Nonlinear Diagnostics Using Ac Dipoles

نویسندگان

  • Todd Satogata
  • Chunmei Tang
  • P. Castro - Garcia
چکیده

There are three goals in the accurate nonlinear diagnosis of a storage ring. First, the beam must be moved to amplitudes many times the natural beam size. Second, strong and long lasting signals must be generated. Third, the measurement technique should be non-destructive. Conventionally, a single turn kick moves the beam to large amplitudes, and turn–by–turn data are recorded from multiple beam position monitors (BPMs) [1-6]. Unfortunately, tune spread across the beam causes the center of charge beam signal to “decohere” on a time scale often less than 100 turns. Filamentation also permanently destroys the beam emittance (in a hadron ring). Thus, the “strong single turn kick” technique successfully achieves only one out of the three goals. AC dipole techniques can achieve all three. Adiabatically excited AC dipoles slowly move the beam out to large amplitudes. The coherent signals then recorded last arbitrarily long. The beam maintains its original emittance if the AC dipoles are also turned off adiabatically, ready for further use. The AGS already uses an RF dipole to accelerate polarized proton beams through depolarizing resonances with minimal polarization loss [7]. Similar AC dipoles will be installed in the horizontal and vertical planes of both rings in RHIC [8]. The RHIC AC dipoles will also be used as spin flippers, and to measure linear optical functions [9].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of an Ac–dipole for Use in Rhic

We present two options for implementing a pair of ACdipoles in RHIC for spin flipping, measuring linear optical functions and nonlinear diagnostics. AC-dipoles are magnets that can be adiabatically excited and deexcited with a continuous sine-wave in order to coherently move circulating beam out to large betatron amplitudes without incurring emittance blow up[1]. The AGS already uses a similar ...

متن کامل

Nonlinear magnetic susceptibility of ferrofluids

In ferrofluids, external magnetic fields can produce a nonlinearity in the dependence of magnetic susceptibilities on the field strength, due to both normal saturation and abnormal saturation. We derive the nonlinear magnetic susceptibility by using a Langevin model. Then, we investigate the nonlinear ac responses of the magnetic susceptibility by means of a perturbation expansion method and an...

متن کامل

Design and Analysis of a Single-Shot Longitudinal Phase Space Measurement Diagnostics at the Argonne Wakefield Accelerator

Abstract. A single-shot longitudinal phase space diagnostics is currently being assembled at the Argonne Wakefield Accelerator (AWA). The diagnostics consists of mapping the longitudinal phase space coordinates to the transverse position space plane using a beamline that incorporates two magnetic dipoles arranged as a dogleg followed by an rf deflecting cavity. The deflecting cavity streaks the...

متن کامل

Nonlinear static and dynamic behaviors of a microresonator under discontinuous electrostatic actuation

This article studied static deflection, natural frequency and nonlinear vibration of a clamped-clamped microbeam under discontinues electrostatic actuation. The electrostatic actuation was induced by applying AC-DC voltage between the microbeam and electrode plate. In contrast to previous works, it was assumed that length of the electrode plate was smaller than that of the microbeam. In additio...

متن کامل

Measurement of Ramp Rate Sensitivity in Model Dipoles With Ebanol-Coated Cable

Ramp rate sensitivity in superconducting dipole magnets has been shown to vary in an unpredictable fashion between magnets constructed using similar fabrication techniques. Test results from a series of model magnets are presented, one of which was constructed using ebanolcoated strands. The ramp rate sensitivity and ac loss observed is described.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999