Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effect.

نویسندگان

  • Susan R Hopkins
  • A Cortney Henderson
  • David L Levin
  • Kei Yamada
  • Tatsuya Arai
  • Richard B Buxton
  • G Kim Prisk
چکیده

In vivo radioactive tracer and microsphere studies have differing conclusions as to the magnitude of the gravitational effect on the distribution of pulmonary blood flow. We hypothesized that some of the apparent vertical perfusion gradient in vivo is due to compression of dependent lung increasing local lung density and therefore perfusion/volume. To test this, six normal subjects underwent functional magnetic resonance imaging with arterial spin labeling during breath holding at functional residual capacity, and perfusion quantified in nonoverlapping 15 mm sagittal slices covering most of the right lung. Lung proton density was measured in the same slices using a short echo 2D-Fast Low-Angle SHot (FLASH) sequence. Mean perfusion was 1.7 +/- 0.6 ml x min(-1) x cm(-3) and was related to vertical height above the dependent lung (slope = -3%/cm, P < 0.0001). Lung density averaged 0.34 +/- 0.08 g/cm3 and was also related to vertical height (slope = -4.9%/cm, P < 0.0001). By contrast, when perfusion was normalized for regional lung density, the slope of the height-perfusion relationship was not significantly different from zero (P = 0.2). This suggests that in vivo variations in regional lung density affect the interpretation of vertical gradients in pulmonary blood flow and is consistent with a simple conceptual model: the lung behaves like a Slinky (Slinky is a registered trademark of Poof-Slinky Incorporated), a deformable spring distorting under its own weight. The greater density of lung tissue in the dependent regions of the lung is analogous to a greater number of coils in the dependent portion of the vertically oriented spring. This implies that measurements of perfusion in vivo will be influenced by density distributions and will differ from excised lungs where density gradients are reduced by processing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The gravitational distribution of ventilation-perfusion ratio is more uniform in prone than supine posture in the normal human lung.

The gravitational gradient of intrapleural pressure is suggested to be less in prone posture than supine. Thus the gravitational distribution of ventilation is expected to be more uniform prone, potentially affecting regional ventilation-perfusion (Va/Q) ratio. Using a novel functional lung magnetic resonance imaging technique to measure regional Va/Q ratio, the gravitational gradients in proto...

متن کامل

Pulmonary perfusion in the prone and supine postures in the normal human lung.

Prone posture increases cardiac output and improves pulmonary gas exchange. We hypothesized that, in the supine posture, greater compression of dependent lung limits regional blood flow. To test this, MRI-based measures of regional lung density, MRI arterial spin labeling quantification of pulmonary perfusion, and density-normalized perfusion were made in six healthy subjects. Measurements were...

متن کامل

Topographical distribution of pulmonary perfusion and ventilation, assessed by PET in supine and prone humans.

Using positron emission tomography (PET) and intravenously injected (13)N(2), we assessed the topographical distribution of pulmonary perfusion (Q) and ventilation (V) in six healthy, spontaneously breathing subjects in the supine and prone position. In this technique, the intrapulmonary distribution of (13)N(2), measured during a short apnea, is proportional to regional Q. After resumption of ...

متن کامل

Marked differences between prone and supine sheep in effect of PEEP on perfusion distribution in zone II lung.

The classic four-zone model of lung blood flow distribution has been questioned. We asked whether the effect of positive end-expiratory pressure (PEEP) is different between the prone and supine position for lung tissue in the same zonal condition. Anesthetized and mechanically ventilated prone (n = 6) and supine (n = 5) sheep were studied at 0, 10, and 20 cm H2O PEEP. Perfusion was measured wit...

متن کامل

Tomography of regional ventilation and perfusion using krypton 81m in normal subjects and asthmatic patients.

Single photon emission computed tomography, a rotating gamma camera, and continuous inhalation or infusion of krypton 81m (half life 13 seconds) were used to measure regional ventilation (V), perfusion (Q), and ventilation-perfusion (V/Q) ratios in five normal subjects in supine, prone, and lateral decubitus postures and in three asthmatic patients (supine posture only) before and after inhalat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 103 1  شماره 

صفحات  -

تاریخ انتشار 2007