Biologic effects of implant debris.
نویسندگان
چکیده
Biologic response to orthopedic implants debris is central to clinical performance. Eventual implant loosening due to aseptic osteolysis has been attributed to local inflammatory responses to wear and corrosion products that are produced by articulating implant interfaces. The response to implant debris is dominated by local immune activation, e.g. macrophages. Immune reactivity has been shown to depend on the number of particles produced or the dose (i.e., the concentration of phagocytosable particles per tissue volume, which can be characterized by knowing the size distribution and amount of debris). Elongated particles (fbers) are generally more pro-inflammatory than round particles, and there is a growing consensus that metals particles are more proinflammatory than polymers in vivo. Generally, to produce an in vitro inflammatory response, particles need to be less than 10 mum, i.e. phagocytosable. However, both soluble and particulate debris derived from Co-Cr-Mo alloy implants can induce monocyte/macrophage activation and secretion of pro-inflammatory cytokines such as IL-1beta, TNFalpha, IL-6 and IL-8 via up-regulation of transcription factor NFkappabeta, and activation of inflammasome danger signaling in human macrophages. Not only does activation of local (and systemic) inflammation result in decreased osteoblast function but osteoclast activity increases. Some people are more predisposed to implant debris induced inflammation and metal "allergy" testing services are becoming available. New pathways of implant debris-induced inflammatory reactions continue to be discovered, such as the "danger signaling" inflammasome pathway, which provides new targets for pharmaceutical intervention and improved implant performance.
منابع مشابه
A review of the biologic effects of spine implant debris: Fact from fiction
BACKGROUND Biologic-reactivity to implant-debris is the primary determinant of long-term clinical performance. The following reviews: 1) the physical aspects of spinal-implant debris and 2) the local and systemic biologic responses to implant debris. METHODS Methods included are: 1) gravimetric wear analysis; 2) SEM and LALLS; 3) metal-ion analysis; 4) ELISA, toxicity testing, patch testing; ...
متن کاملBiologic Width around Dental Implants: An Updated Review
Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...
متن کاملIs wear debris responsible for failure in alumina-on-alumina implants?
BACKGROUND AND PURPOSE Ceramic-on-ceramic articulation is an attractive alternative to metal-on-polyethylene (PE) bearings, but little is known about the in vivo effects induced by dissemination of alumina wear debris in the periprosthetic tissues. We hypothesized that wear debris is not the main factor responsible for loosening and failure of the implant but that mechanical problems caused by ...
متن کاملWear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints
Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the...