The effect of the diffusion time and pulse gradient duration ratio on the diffraction pattern and the structural information estimated from q-space diffusion MR: experiments and simulations.

نویسندگان

  • Amnon Bar-Shir
  • Liat Avram
  • Evren Ozarslan
  • Peter J Basser
  • Yoram Cohen
چکیده

q-Space diffusion MRI (QSI) provides a means of obtaining microstructural information about porous materials and neuronal tissues from diffusion data. However, the accuracy of this structural information depends on experimental parameters used to collect the MR data. q-Space diffusion MR performed on clinical scanners is generally collected with relatively long diffusion gradient pulses, in which the gradient pulse duration, delta, is comparable to the diffusion time, Delta. In this study, we used phantoms, consisting of ensembles of microtubes, and mathematical models to assess the effect of the ratio of the diffusion time and the duration of the diffusion pulse gradient, i.e., Delta/delta, on the MR signal attenuation vs. q, and on the measured structural information extracted therefrom. We found that for Delta/delta approximately 1, the diffraction pattern obtained from q-space MR data are shallower than when the short gradient pulse (SGP) approximation is satisfied. For long delta the estimated compartment size is, as expected, smaller than the real size. Interestingly, for Delta/delta approximately 1 the diffraction peaks are shifted to even higher q-values, even when delta is kept constant, giving the impression that the restricted compartments are even smaller than they are. When phantoms composed of microtubes of different diameters are used, it is more difficult to estimate the diameter distribution in this regime. Excellent agreement is found between the experimental results and simulations that explicitly account for the use of long duration gradient pulses. Using such experimental data and this mathematical framework, one can estimate the true compartment dimensions when long and finite gradient pulses are used even when Delta/delta approximately 1.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of rotational angle and experimental parameters on the diffraction patterns and micro-structural information obtained from q-space diffusion NMR: implication for diffusion in white matter fibers.

Diffusion NMR may provide, under certain experimental conditions, micro-structural information about confined compartments totally non-invasively. The influence of the rotational angle, the pulse gradient length and the diffusion time on the diffusion diffraction patterns and q-space displacement distribution profiles was evaluated for ensembles of long cylinders having a diameter of 9 and 20 m...

متن کامل

Crossing fibers, diffractions and nonhomogeneous magnetic field: correction of artifacts by bipolar gradient pulses.

In recent years, diffusion tensor imaging (DTI) and its variants have been used to describe fiber orientations and q-space diffusion MR was proposed as a means to obtain structural information on a micron scale. Therefore, there is an increasing need for complex phantoms with predictable microcharacteristics to challenge different indices extracted from the different diffusion MR techniques use...

متن کامل

Finer Discrimination of Fiber Orientation at High q Diffusion MR: Theoretical and Experimental Confirmation

Synopsis Recently, it was found that the signal attenuation observed in diffusion MR experiments of a pack of cylindrical impermeable microcapillary tubes have high directional sensitivity. We have modeled this signal decay as a function of q using the restricted component of the newly proposed CHARMED model, which describes intra-axonal diffusion. CHARMED fits the data nicely, and more importa...

متن کامل

Experimental Parameters and Diffraction Patterns at High q Diffusion MR: Experiments and Theoretical Simulations

Introduction q-Space diffusion MR [1, 2], is increasingly being used to obtain structural information in neuronal tissues [3-7] on a micron scale, well below the resolution in conventional MRI. Diffraction pattern in q-space diffusion MR obtained from packs of impermeable micro-capillaries exhibits a strong angular dependence [8]. Recently the 3-D restricted model of water diffusion embodied in...

متن کامل

Evaluation of Angular Uncertainties of q-space Diffusion MRI Under Finite Gradient Pulse Widths : A Phantom Study

Introduction Q-space diffusion-weighted (DW) MR imaging is a valuable technique to evaluate the physiological state and the geometry of tissues. However, in clinical DW imaging protocols, the essential requirement of a short pulse gradient (SPG) is not achievable due to the limited gradient intensity of current MR systems. According to previous studies, finite diffusion gradient pulse widths ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 194 2  شماره 

صفحات  -

تاریخ انتشار 2008