The influence of human physical activity and contaminated clothing type on particle resuspension.
نویسندگان
چکیده
A study was conducted to experimentally quantify the influence of three variables on the level of resuspension of hazardous aerosol particles from clothing. Variables investigated include physical activity level (two levels, low and high), surface type (four different clothing material types), and time i.e. the rate at which particles resuspend. A mixture of three monodisperse tracer-labelled powders, with median diameters of 3, 5, and 10 microns, was used to "contaminate" the samples, and the resuspended particles were analysed in real-time using an Aerodynamic Particle Sizer (APS), and also by Neutron Activation Analysis (NAA). The overall finding was that physical activity resulted in up to 67% of the contamination deposited on clothing being resuspended back into the air. A detailed examination of the influence of physical activity level on resuspension, from NAA, revealed that the average resuspended fraction (RF) of particles at low physical activity was 28 ± 8%, and at high physical activity was 30 ± 7%, while the APS data revealed a tenfold increase in the cumulative mass of airborne particles during high physical activity in comparison to that during low physical activity. The results also suggest that it is not the contaminated clothing's fibre type which influences particle resuspension, but the material's weave pattern (and hence the material's surface texture). Investigation of the time variation in resuspended particle concentrations indicated that the data were separable into two distinct regimes: the first (occurring within the first 1.5 min) having a high, positive rate of change of airborne particle concentration relative to the second regime. The second regime revealed a slower rate of change of particle concentration and remained relatively unchanged for the remainder of each resuspension event.
منابع مشابه
Literatur Review and Parametric Study: Indoor Particle Resuspension by Human Activity
Once an aerosol contaminant is introduced into an indoor environment, it can remain in the air, deposit on interior surfaces or attach to dust particles already present. Human activity, such as walking and cleaning, resuspends contaminated particles, regenerating airborne contaminants. This report is a literature review on the effects of human activity on particle re-suspension in indoor enviro...
متن کاملImaging of accidental contamination with F-18-solution; a quick trouble-shooting procedure
To the best of our knowledge, imaging of accidental exposure to radioactive fluorine-18 (F-18) due to liquid spill has not been described earlier in the scientific literature. The short half-life of F-18 (t½=110 min), current radiation safety requirements, and Good Manufacturing Practice (GMP) regulations on radiopharmaceuticals have restrained the occurrence of these incidents. The possibilit...
متن کاملCharacterizing particle resuspension from mattresses: chamber study.
UNLABELLED People spend approximately one-third of their lives sleeping, where they can be exposed to a myriad of particle-bound biological agents and chemical pollutants that originate within mattresses and bedding, including allergens, fungal spores, bacteria, and particle-phase semi-volatile organic compounds. Full-scale particle resuspension experiments were conducted in an environmental ch...
متن کاملStudies on Particle Resuspension
Particle deposits on indoor surfaces can be as complex and diverse as the indoor environments in which they exist. Dust loading can range over several orders of magnitude, suggesting the existence of different types of particle deposits. These deposits can be broadly classified as either a monolayer, in which particles are sparsely deposited on a surface, or a multilayer, in which particles are...
متن کاملResuspension of Allergen-containing Particles under Mechanical and Aerodynamic Disturbances from Human Walking - Introduction to an Experimental Controlled Methodology
Epidemiological evidence indicates that common environmental allergens found in building reservoirs are strongly associated with the development of bronchial hyper-reactivity (BHR) or asthma, affecting up to half the population in North America and Europe. Although they are rarely life threatening, these diseases cause much distress and lost time from school and work. These diseases are believe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of environmental radioactivity
دوره 127 شماره
صفحات -
تاریخ انتشار 2014