WE-G-BRCD-04: Development of Automated Determination Method of Robust Beam Directions against Patient Setup Errors Based on Spatial Distribution of Electron Density in Particle Therapy.
نویسندگان
چکیده
PURPOSE The three-dimensional (3D) dose distribution covering a tumor region tends to be more breakable if the beam's eye view (BEV) of the 3D electron density (ED) map in a beam direction changes more abruptly with large fluctuations. Our aim of this study was to develop an automated determination method of robust beam directions against the patient setup error based on the ED-based BEV in the beam direction in the particle therapy. METHODS The basic idea of our proposed method was to find the robust beam directions, whose the ED-based BEV has the spatial fluctuations with low special frequency and small amplitude. For evaluation of the spatial fluctuation in the ED-based BEV in a beam direction, we obtained power spectra of the ED-based BEVs in all directions, i.e., 0 to 355 degree, with an interval of 5 degree. It was assumed that as the average spatial frequency and amplitude of the fluctuation in the ED-based BEV in a beam direction is lower and smaller, respectively, the absolute value of a gradient of the power spectrum becomes larger. Therefore the gradient of the power spectrum was calculated for determination of the robust beam direction. The ED-based BEV was produced by projecting a 3D electron density map derived from the computed tomography (CT) image from a beam source to the distal end of a planning target volume (PTV). Four cases of head and neck cancer patients were selected for evaluation of the proposed method. RESULTS As a preliminary result, radiation oncologists agreed with most beam directions, which seem to be robust against patient setup errors, suggested by the proposed method. CONCLUSIONS Our proposed method could be feasible to suggest the robust beam directions against patient setup errors in hadron particle therapy.
منابع مشابه
Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients
Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...
متن کاملDosimetric robustness against setup errors in charged particle radiotherapy of skull base tumors
BACKGROUND It is expected that physical dose deposition properties render charged particle dose distributions sensitive to targeting uncertainties. Purpose of this work was to investigate the robustness of scanned-beam particle therapy plans against setup errors for different optimization modalities, beam setups and ion species. MATERIAL AND METHODS For 15 patients with skull base tumors, loc...
متن کاملOptimal Locations on Timoshenko Beam with PZT S/A for Suppressing 2Dof Vibration Based on LQR-MOPSO
Neutralization of external stimuli in dynamic systems has the major role in health, life, and function of the system. Today, dynamic systems are exposed to unpredicted factors. If the factors are not considered, it will lead to irreparable damages in energy consumption and manufacturing systems. Continuous systems such as beams, plates, shells, and panels that have many applications in differen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 6Part28 شماره
صفحات -
تاریخ انتشار 2012