Reconstruction of deforming aortas in two-photon autofluorescence image sequences.

نویسندگان

  • Jue Wang
  • Liang Ji
  • Hui Ma
چکیده

Information loss may occur frequently in the imaging of living tissues by using two-photon fluorescence microscopy due to the intensive deformation of the tissue. A landmark-based optical flow interpolation scheme is proposed for image reconstruction of living aorta walls in two-photon autofluorescence image sequences. Landmarks are extracted and evaluated by an active contour-based aorta model, and are aligned and reconstructed by use of a hierarchical algorithm. The accuracy of the calculation of optical flow is improved by applying landmark-based image warping. Experimental results show that the proposed scheme outperforms commonly used optical flow interpolation techniques for the reconstruction of intensively deforming tissues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracking deforming aortas in two-photon autofluorescence images and its application on quantitative evaluation of aorta-related drugs.

This paper describes a novel approach to an objective measurement of aorta samples of rats and a quantitative evaluation of aorta-related drugs. Two-photon fluorescence microscopy is used for recording image sequences of deforming aorta. Time sequence snake models are used to track the structural deformations of aorta walls caused by drug stimulation of the elastic lamina in the aorta. Several ...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

The Study of Variation of Photon Intensity Inside Biological Phantom by Green Theorem

The Image reconstruction is an important problem in optical tomography. The process of the image processing requires the study of photon migration in biological tissue. There are several approaches to study and simulate propagation of photons in biological tissues. These approaches are categorized into stochastic and analytical groups. The Monte Carlo method as a stochastic method is widely use...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 42 5  شماره 

صفحات  -

تاریخ انتشار 2003