Evaluation of signal formation in local arterial input function measurements of dynamic susceptibility contrast MRI.
نویسندگان
چکیده
Correct arterial input function (AIF) measurements in dynamic susceptibility contrast-MRI are crucial for quantification of the hemodynamic parameters. Often a single global AIF is selected near a large brain-feeding artery. Alternatively, local AIF measurements aim for voxel-specific AIFs from smaller arteries. Because local AIFs are measured higher in the arterial-tree, it is assumed that these will reflect the true input of the microvasculature much better. However, do the measured local AIFs reflect the true concentration-time curves of small arteries? To answer this question, in vivo data were used to evaluate local AIF candidates selected based on two different types of angiograms. For interpretation purposes, a 3D numerical model that simulated partial-volume effects in local AIF measurements was created and the simulated local AIFs were compared to the ground truth. The findings are 2-fold. First, the in vivo data showed that the shape-characteristics of local AIFs are similar to the shape-characteristics of gray matter concentration-time curves. Second, these findings are supported by the simulations showing broadening of the measured local AIFs compared to the ground truth. These findings are suggesting that local AIF measurements do not necessarily reflect the true concentration-time curve in small arteries.
منابع مشابه
An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors
Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...
متن کاملEffects of Contrast Agent Accumulation on Background Correction of Phase-Based Arterial Input Functions
Introduction The quality of pharmacokinetic parameters derived from Dynamic Contrast-Enhanced MRI (DCE-MRI) and perfusion estimates from Dynamic Susceptibility Contrast MRI (DSC-MRI) depends strongly on the accuracy of the measured Arterial Input Function (AIF). Traditionally, the AIF is calculated from magnitude signal intensity but this is complicated by issues such as signal saturation, non-...
متن کاملMeasurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: comparison of physical simulations with in vivo results.
Measurement of the arterial input bolus shape is essential to the quantification of mean transit time and blood flow with dynamic susceptibility contrast (DSC) MRI. Input functions derived from the echoplanar signal intensity within or near arteries are highly nonlinear, yet such input functions are widely used. We employed a physical model for the echoplanar signal intensity from an artery as ...
متن کاملDynamic susceptibility contrast MRI with localized arterial input functions.
Compared to gold-standard measurements of cerebral perfusion with positron emission tomography using H(2)[(15)O] tracers, measurements with dynamic susceptibility contrast MR are more accessible, less expensive, and less invasive. However, existing methods for analyzing and interpreting data from dynamic susceptibility contrast MR have characteristic disadvantages that include sensitivity to in...
متن کاملIn vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI.
For pharmacokinetic modeling of tissue physiology, there is great interest in measuring the arterial input function (AIF) from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) using paramagnetic contrast agents. Due to relaxation effects, the measured signal is a nonlinear function of the injected contrast agent concentration and depends on sequence parameters, system calibratio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 67 5 شماره
صفحات -
تاریخ انتشار 2012