Performance of the GeneXpert CT/NG assay compared to that of the Aptima AC2 assay for detection of rectal Chlamydia trachomatis and Neisseria gonorrhoeae by use of residual Aptima Samples.

نویسندگان

  • S D Goldenberg
  • J Finn
  • E Sedudzi
  • J A White
  • C Y W Tong
چکیده

There are currently no commercially available molecular assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in rectal swabs with regulatory approval. We compared the Cepheid GeneXpert CT/NG assay with the GenProbe Aptima Combo2 assay, using 409 rectal swabs. Using Aptima as the gold standard, the sensitivity, specificity, and positive and negative predictive values of GeneXpert for the detection of C. trachomatis and N. gonorrhoeae were 86%, 99.2%, 92.5%, and 98.4% and 91.1%, 100%, 100%, and 98.6%, respectively. Despite significant dilution of samples prior to GeneXpert testing, the assay performed well with excellent specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

The Gen-Probe APTIMA Combo 2 (AC2) is a Food and Drug Administration-cleared nucleic acid amplification test (NAAT) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae from urine and urogenital swab specimens. The Centers for Disease Control and Prevention have recommended confirmation of positive NAAT results in low-prevalence populations. APTIMA CT (ACT) and APTIMA GC (AGC) a...

متن کامل

Use of nucleic acid amplification testing for diagnosis of anorectal sexually transmitted infections.

Nucleic acid amplification testing (NAAT) has become the preferred method to detect Chlamydia trachomatis and Neisseria gonorrhoeae, but no commercial tests are cleared by the U.S. Food and Drug Administration for use with rectal swab samples. This study evaluated the performance of strand displacement amplification (SDA) and transcription-mediated amplification (TMA) to detect C. trachomatis a...

متن کامل

First report of performance of the Versant CT/GC DNA 1.0 assay (kPCR) for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

We evaluated the analytical, work flow, and clinical performance of the Versant CT/GC DNA 1.0 assay (Versant CT/GC assay, where "CT" represents Chlamydia trachomatis and "GC" represents Neisseria gonorrhoeae). The assay simultaneously detects Chlamydia trachomatis and Neisseria gonorrhoeae in swab and first-catch urine (FCU) specimens. The limit of detection (LoD) was determined to be 342 copie...

متن کامل

Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, ...

متن کامل

Comparison of the Abbott m2000 RealTime CT assay and the Cepheid GeneXpert CT/NG assay to the Roche Amplicor CT assay for detection of Chlamydia trachomatis in ocular samples from Tanzania.

The GeneXpert CT/NG assay (GeneXpert) and the Abbott m2000 RealTime CT (m2000) assay were compared to Amplicor for detecting ocular Chlamydia trachomatis. Discordant specimens were tested by the Aptima CT assay. The m2000 assay sensitivity was 100% (95% confidence interval [CI], 90% to 100%), and specificity was 98.46% (95% CI, 95.2% to 99.2%); GeneXpert sensitivity was 100% (95% CI, 90% to 100...