Probing chemical induced cellular stress by non-Faradaic electrochemical impedance spectroscopy using an Escherichia coli capacitive biochip.
نویسندگان
چکیده
A new capacitive biochip was developed using carboxy-CNT activated gold interdigitated (GID) capacitors immobilized with E. coli cells for the detection of cellular stress caused by chemicals. Here, acetic acid, H(2)O(2) and NaCl were employed as model chemicals to test the biochip and monitored the responses under AC electrical field by non-Faradaic electrochemical impedance spectroscopy (nFEIS). The electrical properties of E. coli cells under different stresses were studied based on the change in surface capacitance as a function of applied frequency (300-600 MHz) in a label-free and noninvasive manner. The capacitive response of the E. coli biochip under normal conditions exhibited characteristic dispersion peaks at 463 and 582 MHz frequencies. Deformation of these signature peaks determined the toxicity of chemicals to E. coli on the capacitive biochip. The E. coli cells were sensitive to, and severely affected by 166-498 mM (1-3%) acetic acid with declined capacitance responses. The E. coli biochip exposed to H(2)O(2) exhibited adaptive responses at lower concentrations (<2%), while at a higher level (882 mM, 3%), the capacitance response declined due to oxidative toxicity in cells. However, E. coli cells were not severely affected by high NaCl levels (513-684 mM, 3-4%) as the cells tend to resist the salt stress. Our results demonstrated that the biochip response at a particular frequency enabled the determination of the severity of the stress imposed by chemicals and it can be potentially applied for monitoring unknown chemicals as an indicator of cytotoxicity.
منابع مشابه
A new interpretation of electrochemical impedance spectroscopy to measure accurate doping levels for conducting polymers: Separating Faradaic and capacitive currents
We report an electrochemical impedance spectroscopy (EIS) based method to measure the doping level of conducting polymers. Using EIS the Faradaic current and the capacitive charging current can be separated without relying on any unverifiable assumptions. We demonstrate the method for three types of conducting polymer thin films that are the basis for many commercial applications (poly(3,4ethyl...
متن کاملStress Corrosion Cracking Detection of Sensitized Stainless Steel 304 in Chloride Media by Using Electrochemical Impedance Spectroscopy (EIS)
Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...
متن کاملDeviations of capacitive and inductive loops in the electrochemical impedance of a dissolving iron electrode.
The electrochemical impedance of an iron electrode often shows the capacitive and inductive loops on the complex plane. The capacitive loop originates from the time constant of the charge transfer resistance and the electric double layer capacitance. The inductive loop is explained by Faradaic processes involving the reaction intermediate. In some cases, these loops deviate from a true semicirc...
متن کاملFaradaic and Capacitive Components of the CNT Electrochemical Responses
The nature of the electrochemical responses from carbon nanotubes (CNTs), capacitive (physical), or Faradaic (chemical, also named p-doping or n-doping) remain controversial. In this chapter, the literature is reviewed and discussed trying to elucidate if some of the two processes prevails, how the presence of chemical reactions can be elucidated and which properties, specific from the chemical...
متن کاملAmyloid Beta Detection by Faradaic Electrochemical Impedance Spectroscopy Using Interdigitated Microelectrodes
Faradaic electrochemical impedance spectroscopy (f-EIS) in the presence of redox reagent, e.g., [Fe(CN)₆]3-/4-, is widely used in biosensors owing to its high sensitivity. However, in sensors detecting amyloid beta (Aβ), the redox reagent can cause the aggregation of Aβ, which is a disturbance factor in accurate detection. Here, we propose an interdigitated microelectrode (IME) based f-EIS tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 136 13 شماره
صفحات -
تاریخ انتشار 2011