Total internal reflection and evanescent gain.

نویسندگان

  • Jon Olav Grepstad
  • Johannes Skaar
چکیده

Total internal reflection occurs for large angles of incidence, when light is incident from a high-refractive-index medium onto a low-index medium. We consider the situation where the low-index medium is active. By invoking causality in its most fundamental form, we argue that evanescent gain may or may not appear, depending on the analytic and global properties of the permittivity function. For conventional, weak gain media, we show that there is an absolute instability associated with infinite transverse dimensions. This instability can be ignored or eliminated in certain cases, for which evanescent gain prevails.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Thin Layer Imaging with the Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy (TIRFM) is an optical technique that allows imaging of a thin layer of the sample with a thickness of about 100-200 nm. It is used in science of cell biology to study cellular processes, especially near the membranes of living cells. This method is based on the total internal reflection phenomenon, where the evanescent wave is generated in the l...

متن کامل

Circular and near-circular polarization states of evanescent monochromatic light fields in total internal reflection.

Conditions for the production of near-circular polarization states of the evanescent field present in the rarer medium in total internal reflection of incident monochromatic p-polarized light at a dielectric-dielectric planar interface are determined. Such conditions are satisfied if high-index (>3.2) transparent prism materials (e.g., GaP and Ge) are used at angles of incidence well above the ...

متن کامل

Total internal reflection photonic crystal prism.

An integrated total internal reflection prism is demonstrated that generates a transversely localized evanescent wave along the boundary between a photonic crystal and an etched out trench. The reflection can be described by either the odd symmetry of the Bloch wave or a tangential momentum matching condition. In addition, the Bloch wave propagates through the photonic crystal in a negative ref...

متن کامل

TIRF microscopy evanescent field calibration using tilted fluorescent microtubules.

Total internal reflection fluorescence microscopy has become a powerful tool to study the dynamics of sub-cellular structures and single molecules near substrate surfaces. However, the penetration depth of the evanescent field, that is, the distance at which the excitation intensity has exponentially decayed to 1/e, is often left undetermined. This presents a limit on the spatial information ab...

متن کامل

Two-photon Scanning Fluorescence Microscopy under Total Internal Reflection

Two-photon fluorescence microscopy is a powerful method for many applications. Because of the ability of strong attenuation of the background fluorescence, total internal reflection fluorescence microscopy (TIRFM) has been the major technique in the fluorescence imaging and single molecule detections. Recently, we have developed a new type of TIRFM called scanning TIRFM (henceforth abbreviated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 19 22  شماره 

صفحات  -

تاریخ انتشار 2011