اثر ترکیب لیزرهای هلیوم- نئون و دیود بر تولید آنتوسیانین و رشد سلول در کشت سوسپانسیون سیب گوشت قرمز (Malus sp.)

نویسندگان

چکیده مقاله:

The red-fleshed apples are from varieties of apples confer the competence and high ability in vitro to produce anthocyanins in their organs. Several factors affect the in vitro production of anthocyanins in plant tissue culture and to produce high, the optimizing of these factors are very necessary. Light is one of the most important factors that many studies have been done in this area but the laser irradiation effects has not been investigated. We have studied the effect of combine lasers treatment of He-Ne with diode on in vitro production anthocyanin and cellular growth of cell suspension of red-fleshed apple. This experiment with 18 combinations treatments (blue laser at the intensities of 67.09, 32.74, 30.4 and 13.73 mW/cm2 and a red laser at the intensities of 6.46, 4.82, 1.54 and 0.666 mW/cm2 and two controls including darkness and fluorescent light) as a factorial design based on CRD with three replications for each treatment were applied.With increasing of combination lasers radiation intensity, production rates monomeric total anthocyanins (TMA) and total anthocyanins (TA) increased but lead to was reduced the cell growth. Results of this work showed that probably high intensity of combination lasers radiation treatments as a stress factor made decreased cell growth and induced high concentration of anthocyanins in the cell exposed to stress and good for decreasing injures proceed from stress and also lead to persevered cell of red-fleshed apple through high concentration accumulation of anthocyanin in vacuole.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اثر ترکیب شدت های مختلف نورهای لیزری آبی و قرمزبر تولید آنتوسیانین در کشت سوسپانسیون سلولی سیب(malus sp.)

با توجه به اهمیت اقتصادی متابولیت های ثانوی و نیز محدود بودن گونه های گیاهی در رویشگاه های طبیعی آن‎ها، روش کشت سلول، راه مناسبی برای تولید ترکیبات شیمیایی ارزشمند می‎باشد. بعضی از گونه ها و واریته های سیب استعداد و توانایی بالایی در تولید آنتوسیانین در اندام های خود دارند. آنتوسیانین ها متعلق به خانواده ترکیبات فلاونوئیدی بوده و به دلیل داشتن خاصیت آنتی اکسیدانی دارای اهمیت هستند. عوامل مختلفی...

بررسی اثرات تابش لیزرهای کم توان هلیوم-نئون بر بهبود و ترمیم اعصاب محیطی آسیب دیده

The nervous system has an important and vital role in the human body, but unfortunately the repairment of damaged nervous tissue is very slowly. For a long time, the scientists have been involved in finding ways to speed up this process. Radiation of low power He-Ne laser has been suggested to as a way to improve this issue. In this study, 20 rats were divided randomly into control and case gro...

متن کامل

مقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure

کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...

متن کامل

جداسازی و بررسی بیان واریانت MdMYB10bدر سیب گوشت قرمز و مطالعه اللیسم ژنهای مسئول رنگ قرمز در سیب

خانواده ژنی MYB بعنوان یکی از بزرگترین فاکتورهای رونویسی در گیاهان نقش¬های متعددی بر عهده دارند که یکی از مهمترین آنها تنظیم سطح آنتوسیانین در پیکره گیاه است. در سیب (Malus ×domestica) سه ژن MdMYB1، MdMYBA و MdMYB10 با کنترل سطح آنتوسیانین مسئول توسعه رنگ قرمز می¬باشند.در این مطالعه ضمن جداسازی یک واریانت از ژن MdMYB10، با نام MdMYB10b، از یک سیبگوشت قرمز بومی ایران الگوی بیانی آن در بافت¬های ...

متن کامل

طرح وساختمان و طرز کاریک لیزر هلیوم - نئون

لیزرهلیوم - نئون را می توان لیزر مرئی با پرتو مداوم دانست

متن کامل

بررسی پارامترهای مختلف لیزر هلیوم-نئون

در این مقاله پارامترهای مختلف لیزر هلیوم – نئون و روش­های اندازه­گیری این پارامترها، در آزمایشگاه مورد بررسی قرار گرفته است. توسط روش­هایی که بیان خواهد شد، توان متوسط خروجی این لیزر با استفاده از توان سنج لیزری، mW 7 /5 ، در پایش پایداری زمانی آن V 52/18 اندازه­گیری شده است. برای اندازه­گیری زاویه واگرایی دو روش به کار گرفته شده است که  شامل مقایسه با نمونه مرجع و روش هندسی است. مقدار متوسط زا...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 21

صفحات  237- 246

تاریخ انتشار 2017-11

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023