A method for range calculation of proton in liquid water: Validation study using Monte Carlo method and NIST data

نویسندگان

  • Hadi Taleshi Ahangari Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
  • Hossein Mousavie Anijdan Department of Medical Physics, Babol University of Medical Sciences, Babol, Iran
  • Mohammad Ali Tajik Mansoury Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
  • Sayyed Bijan Jia Professor of physics, Department of Physics, Bojnord University, Bojnord, Iran.
  • Shiva Zarifi MSc. Student of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
چکیده مقاله:

Introduction: The main advantage of using ion beams over photons in radiotherapy is due to their inverse depth-dose profiles, allowing higher doses to tumors, while better sparing normal tissues. When calculating dose distributions with ion beams, one crucial point is the uncertainty of the Bragg-peak range. Recently great effort is devoted to enhance the accuracy of the computation for proton treatments without increasing the calculation time. The highest accuracy in these calculations is obtained by Monte Carlo simulation methods. GATE is a Monte Carlo simulation platform based on geant4 which was found to be a convenient simulation environment to perform this study. This study shows how a stochastic method such as Monte Carlo can be utilized to obtain certain quantities of practical importance related to charged particle transport Materials and Methods: In this study, GATE code was used to compute absorbed dose and fluence of protons in the energy range of 50-200 MeV and with energy step of 50 MeV. A water phantom (40*40*40 cm3) was modeled in a vacuum world volume (5*5*5 m3). Several physics lists have been defined in the GATE code that we used FTFP_BERT. The mono-energetic protons were emitted mono-directionally from a point source at one end of the water phantom. The simulations were carried out for 10^6 proton histories that yielded better than 0.3% statistical errors. Results: In this study, we validated the Gate code in proton therapy applications. This study examined different physics lists and showed that the results obtained using FTFP_BERT physics are in a good agreement with NIST database. Our Results were compared to the CSDA ranges from NIST database using the GATE simulation code. The FTFP_BERT results showed good agreement within 1% for energies higher than 30 MeV and within 0.1% for energies higher than 70 MeV .We also conclude that the value of 0.1 mm is optimal for the SetCut. Conclusion: The results were found to be ±0.1% compared to the data from the NIST compilation. It is safe to conclude that this approach can be extended to determine dosimetric quantities for other media, energies and charged particle types.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method for range calculation based on empirical models of proton in liquid water: Validation study using Monte-Carlo method and ICRU data

The biological damages are mainly produced by direct ionization and excitation of bio-molecular DNA electrons or by indirect chemical reaction of water radiolysis products with DNA. In this work, we restricted our study on the interaction of energetic ion proton beams with liquid water; since the water represents over 80% of the most-soft tissues. The proton collisions with water molecules are ...

متن کامل

Monte Carlo calculation of proton ranges in water phantom for therapeutic energies

Introduction: One crucial point when calculating the distribution of doses with ions is the uncertainty of the Bragg peak. The proton ranges in determined geometries like homogeneous phantoms and detector geometries can be calculated with a number of various parameterization models. Several different parameterizations of the range-energy relationship exist, with different level...

متن کامل

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method

Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherap...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

Monte-Carlo Calculation of Radon Absorbed Dose in Optical Fiber as a Novel Method in Dosimetry and Radon Measurement

Introduction Radon is a colorless and tasteless gas which exists in most soils. It is a substance that poses a potential risk for lung cancer in case a person is exposed to high levels over long periods of time. The Environmental Protection Agency (EPA) estimates that 90% of lung cancers per year are caused by radon. The aim of this paper is to estimate the absorbed doses of 222Rn by MCNPX simu...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  360- 360

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023