A Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy

نویسندگان

  • Hossein Rajabi Medical Physics Department, Tarbiat Modares University, Tehran, Iran
  • Masoud Jabari Medical Physics Department, Tarbiat Modares University, Tehran, Iran
چکیده مقاله:

Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptide therapy. Average dose to a kidney is not a perfect index to quantify the damage due to radiation. Obviously, a damage to a small area of nephron can lead to its dysfunction while the average dose may be lower than the tolerance level. The aim of this study is to estimate the absorbed dose along a typical nephron as an index to predict the possible damages to the nephron.   Materials and Methods: Using Gate/GEANT4 Monte Carlo toolkit an idealized nephron model is created using geometrical and anatomical parameters taken from the literature. These samples also provide the data for volume of occupancy of the different compartments of the nephron in the kidney: glomerulus vs. proximal tubule vs. distal tubule. The selected pharmaceuticals were considered attached to radionuclide of choice (Tc-99m, Y-90, Lu-177, In-111). Radionuclides were distributed in the different components of nephron, Monte Carlo simulations were run, the absorbed doses to the model components (self-absorption and cross-absorption) were calculated. Different physics model in Geant4(Penelope, Livermore and Geant4-DNA) were compared together as an evaluation of the results.   Results: Preliminary results show an absorbed dose to the proximal tubule and glomerular cells approximately 2 times greater than that to the kidney as a whole. This difference in conjunction with the relative biological effect (a factor of about 5) would be consistent with the toxicity observed in the experiments. We observed a strong linear relationship between the results obtained using the condenced-history physics model and those derived using the track-structure. This similarity is verified by previous study in spherical geometry for cellular dosimetry. The agreement between data series was evaluated by Blant-Altman analysis.   Conclusion: The nephron model enables optimal implementation of treatment and is a critical step in understanding nephron toxicity for human translation of radiopharmaceutical therapy

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

the innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran

آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...

15 صفحه اول

Optimization of Bremsstrahlung imaging in Yttrium internal radiation therapy

Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...

متن کامل

Microdosimetry for Targeted Alpha Therapy of Cancer

Targeted alpha therapy (TAT) has the advantage of delivering therapeutic doses to individual cancer cells while reducing the dose to normal tissues. TAT applications relate to hematologic malignancies and now extend to solid tumors. Results from several clinical trials have shown efficacy with limited toxicity. However, the dosimetry for the labeled alpha particle is challenging because of the ...

متن کامل

Microdosimetry for boron neutron capture therapy.

Preclinical studies for boron neutron capture therapy (BNCT) using epithermal neutrons are ongoing at several laboratories. The absorbed dose in tumor cells is a function of the thermal neutron flux at depth, the microscopic boron concentration, and the size of the cell. Dosimetry is therefore complicated by the admixture of thermal, epithermal, and fast neutrons, plus gamma rays, and the array...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  30- 30

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023