A new approach to scatter correction in SPECT images based on Klein_Nishina equation

نویسندگان

  • Hadi Taleshi Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
  • Mohsen Saffar Medical Physics Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Peter Knoll Department of Nuclear Medicine, Wilhelminenspital, Vienna, Austria
  • Shabnam Oloomi Medical Physics Department, Mashhad University of Medical Science, Mashhad, Iran
چکیده مقاله:

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique that use an accurate analytical model based on Klein_Nishina scatter equation and compare Klein_Nishina scatter estimation with triple energy window. In order to verify the proposed scattering model several cylindrical phantoms were simulated. The linear source in the cylindrical Phantoms was a hot rod filled with 99mTc. K factor defines as the ratio of scatter resulting from MC simulation to scatter estimated from Klein_Nishina formula. Also a SPECT/CT scan of the image quality phantom was acquired. Row data were transferred to a PC computer for scatter estimation & processing of the images using MLEM iterative algorithm in MATLAB software. Results: The scatter and attenuation compensated images by the proposed model had better contrast than uncorrected and only attenuation corrected images. The K-factors that used in proposed model doesn’t vary with different activities & diameters of linear source and they’re just a function of depth and composition of pixels. Conclusion: Based on Mont Carlo simulation data, the K_N formula that used in this study demonstrates better estimation of scattered photons than TEW. Proposed scattered correction algorithm will improve 52.3% in the contrast of the attenuated corrected images of image quality phantom.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a new approach to scatter correction in spect images based on klein_nishina equation

introduction: scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. accurate estimation of scatter in projection data of spect is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. methods: the objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

a new approach to scatter correction in spect images based on klein_nishina equation

introduction: scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. accurate estimation of scatter in projection data of spect is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. methods: the objective of this paper is to develop and validate a scatter correction technique t...

متن کامل

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

a new approach for scatter removal and attenuation compensation from spect/ct images

objective(s): in spect, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. many techniques for attenuation and scatter correction have been proposed. an acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. here, we propose new maximum likelihood expectation maximization (mlem) ...

متن کامل

Scatter Correction for Heart SPECT images Using TEW method

Radionuclide imaging has the potential to be used in quantitative analysis of the regional function of organs. However, quantification of SPECT images is degraded by many factors such as Compton photon scattering. This could have a destructive effect on clinical reports so it is important to do scatter correction to get better quality SPECT images. We intended to determine how scatter correctio...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 21  شماره 1

صفحات  19- 25

تاریخ انتشار 2013-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023