A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

نویسندگان

  • Ahmad Esmaili Torshabi Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran, 7631818356
  • Seyyed Amirreza Dastyar Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran, 7631818356
چکیده مقاله:

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Therapy with external surrogates has been proposed to compensate motion error. In this strategy, prediction model is one of main component as responsible to track tumor motion in real time. In this study, a prediction model based on the fuzzy logic concept is proposed for real time tumor tracking during tumor treatment. Several approaches have been proposed for this aim using linear and non-linear prediction models, but a fuzzy environment may be optimal due to its robustness and benefits.   Materials and Methods: The fuzzy model is configured using training dataset provided by monitoring systems with detecting tumor motion and external rib cage motion of ten patients treated with Cyberknife Synchrony System at Georgetown University Hospital. After configuring, the model is ready to trace tumor motion during therapeutic beam irradiation. In our study, we investigated the effect of the number of data clusters, fuzzy inference system type on the performance accuracy of our model. In order to assess the performance of our model, the predicted tumor motion was compared with respect to the state of the art model.   Results: In this work we utilized Root Mean Square Error (RMSE) as common available mathematical metric for illustrating the performance uncertainty error of fuzzy prediction model. As resulted, the mean value of RMSE over ten patients is 5.45 mm Moreover, by implementing sugeno method the RMSE is remarkably less than the same calculation by means of Mamdani method. Moreover, the computational time will be significantly decreased using Sugeno type. As example, the run time improvement is almost 33% for one typical patient with left lob lung cancer.   Conclusion:A fuzzy logic based prediction model was assessed in this work to predict tumor motion as real time during external radiotherapy. The benefits of implemented fuzzy inference system in model learning and its simplicity during running has made it feasible, robust and very promising for real clinical application.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

the effect of consciousness raising (c-r) on the reduction of translational errors: a case study

در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...

15 صفحه اول

a study on the effectiveness of textual modification on the improvement of iranian upper-intermediate efl learners’ reading comprehension

این پژوهش به منظور بررسی تأثیر اصلاح متنی بر بهبود توانایی درک مطلب زبان آموزان ایرانی بالاتر از سطح میانی انجام پذیرفت .بدین منظور 115 دانشجوی مرد و زن رشته مترجمی زبان انگلیسی در این پزوهش شرکت نمودند.

Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates.

It has been noted that some lung tumors exhibit large periodic motion due to respiration. To limit the amount of dose to healthy lung tissues, many clinics have begun gating radiotherapy treatment using externally placed surrogates. It has been observed by several institutions that the end-of-exhale (EOE) tumor position is more reproducible than other phases of the breathing cycle, so the gatin...

متن کامل

a study on the effectiveness of task types (noticing-reformulation) on iranian low intermediate efl learners’ retention of collocations

چکیده پژوهش شبه تجربی حاضر به بررسی بکارگیری تمارین کلاسی که برانگیزنده آگاهی و توجه آگاهانه به همایندها بعنوان بخشی از یک دوره ی مکالمه زبان خارجی در یکی از آموزشگاه های زبان انگلیسی ایران است می پردازد.

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  82- 82

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023