An Intelligent Anti-Islanding Scheme for Synchronous-Based Distributed Generation Using Reduced-Noise Morphological Gradient

نویسندگان

  • M. Sarlak Faculty of Electrical and Computer Engineering, Jundi-Shapur University of Technology, Dezful, Iran.
  • S. Shadpey Faculty of Electrical and Computer Engineering, Jundi-Shapur University of Technology, Dezful, Iran.
چکیده مقاله:

This paper presents a pattern recognition-based scheme for detection of islanding conditions in synchronous- based distributed generation (DG) systems. The main idea behind the proposed scheme is the use of spatial features of system parameters such as the frequency, magnitude of positive sequence voltage, etc. In this study, the system parameters sampled at the point of common coupling (PCC) were analyzed using reduced-noise morphological gradient (RNMG) tool, first. Then, the spatial features of the RNMG magnitudes were calculated. Next, to optimize and increase the ability of the proposed scheme for islanding detection, the best features with a much discriminating power were selected based on separability index (SI) calculation. Finally, to distinguish the islanding conditions from the other normal operation conditions, a support vector machine (SVM) classifier was trained based on the selected features. To investigate the power of the proposed scheme for islanding detection, the results of examinations on the various islanding conditions including system loading and grid operating state were presented.  These results show that the proposed algorithm reliably detect the islanding condition within 32.7 ms.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hybrid Anti-islanding Method for Inverter-Based Distributed Generation

Nowadays, high penetration of Distributed Generations (DG)s in power systems caused some protection issues. One of these issues is unintentional islanding. As regards IEEE 1547 standard, this situation must be recognized immediately, and DG must be separated from the load in less than 2 seconds. In this paper, to detection of islanding in an inverter-based distributed generation, a new hybrid m...

متن کامل

Radial Basis Neural Network Based Islanding Detection in Distributed Generation

This article presents a Radial Basis Neural Network (RBNN) based islanding detection technique. Islanding detection and prevention is a mandatory requirement for grid-connected distributed generation (DG) systems. Several methods based on passive and active detection scheme have been proposed. While passive schemes have a large non detection zone (NDZ), concern has been raised on active method ...

متن کامل

Anti-islanding and Distributed Generation System

This paper proposes an anti-islanding control for a grid connected distributed generation system. The proposed control is based on d-q frame. The scheme using current command reference as positive feedback is utilized to drift the PCC voltage beyond the threshold limits to detect islanding within 2 seconds as prescribed by IEEE 1547. The test system configuration and parameters for anti-islandi...

متن کامل

Islanding Detection Method of Distributed Generation Based on Wavenet

Due to the increasing need to distributed energy resources in power systems, their problems should be studied. One of the main problem of distributed energy resources is unplanned islanding. The unplanned islanding has some dangers to the power systems and the repairman which are works with the incorrect devices. In this paper, a passive local method is proposed. The proposed method is based on...

متن کامل

A Multistage Passive Islanding Detection Method for Synchronous-Based Distributed Generation

A novel, multistage approach to passive islanding detection is presented which uses a decision-tree-like classification algorithm. The novelty of the proposed method is centered on the way in which features are passed to subsequent stages of the decision tree (DT). A traditional DT uses a single feature set while in the modified algorithm, feature sets extracted using different sized time windo...

متن کامل

Islanding detection of synchronous distributed generators

This paper analyses the performance of local passive islanding detection methods for synchronous distributed generators, under different grid and load scenarios. These methods monitor electrical parameters at the interconnection point of a distributed generator and detect island situation whenever these parameters change correspondingly. Lately, islanding detection research has been focused on ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 4

صفحات  524- 535

تاریخ انتشار 2020-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023