Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume

نویسندگان

  • Ali Akbar Khadem Maboudi Department of Biostatistics, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Ali Khorshidi Department of Epidemiology, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Hamidreza Nasseh Urology Research Center, Guilan University of Medical Sciences, Rasht, Iran
  • Maryam Shakiba Department of Epidemiology, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Samaneh Esmaeili Urology Research Center, Guilan University of Medical Sciences, Rasht, Iran
  • Yaser Korouji Urology Research Center, Guilan University of Medical Sciences, Rasht, Iran
چکیده مقاله:

Background: Estimating prostate volume using less invasive transabdominal ultrasonography (TAUS) instead of transrectal ultrasonography (TRUS) is of interest in terms of identifying their agreement level. Previous reports on this subject, applied general correlation coefficient as the level of agreement. This study uses Bland-Altman method to quantify TAUS and TRUS agreement on estimating prostate volume.Methods: Total prostate gland volume of 40 patients with signs and symptoms of benign prostatic hyperplasia were measured using TAUS and TRUS. The study was carried out at the Urology Research Center, Razi Hospital, Guilan University of Medical Sciences (Rasht, Iran) from March to October 2010. Both methods were performed in one session by the same experienced radiologist. Data were analyzed using Pearson correlation coefficient and Bland-Altman method.Results: Total prostate volume estimated by TAUS and TRUS were 50.30±23 and 50.73±24.6 mL, respectively. The limits of agreement for the total prostate volume were -6.86/9.84 that was larger than predefined clinical acceptable margin of 5 mL.Conclusion: There is a lack of agreement between TAUS and TRUS for estimating the total prostate volume. It is not recommended to apply TAUS instead of TRUS for estimating prostate volume.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

application of bland-altman method in comparing transrectal and transabdominal ultrasonography for estimating prostate volume

background: estimating prostate volume using less invasive transabdominal ultrasonography (taus) instead of transrectal ultrasonography (trus) is of interest in terms of identifying their agreement level. previous reports on this subject, applied general correlation coefficient as the level of agreement. this study uses bland-altman method to quantify taus and trus agreement on estimating prost...

متن کامل

Comparison of Transabdominal and Transrectal Ultrasonography of the Prostate Gland in Dogs

Objective- To compare transabdominal (TA) and transrectal (TR) ultrasonography of the prostate gland. Design- Experimental study. Animals- 10 intact male dogs that required euthanasia for reasons other than prostatic disease. Procedures- Prostatic length (L), width (W) and height (H) were measured in T A (L1, W1 and H1) and TR (L2 and H2...

متن کامل

Correlations between the Various Methods of Estimating Prostate Volume: Transabdominal, Transrectal, and Three-Dimensional US

OBJECTIVE To evaluate the correlations between prostate volumes estimated by transabdominal, transrectal, and three-dimensional US and the factors affecting the differences. MATERIALS AND METHODS The prostate volumes of 94 consecutive patients were measured by both transabdominal and transrectal US. Next, the prostate volumes of 58 other patients was measured by both transrectal and three-dim...

متن کامل

Validating the Bland-Altman Method of Agreement

Bland-Altman’s analysis and plot are the most common methods used to assess the relative agreement between two analytical methods that measure the continuous variables measured on the same scale. Many agreement studies have shown that using the t-test or the Pearson’s product-moment correlation is flawed when measuring the agreement or detecting the bias. Bland-Altman proposed graphical techniq...

متن کامل

Understanding Bland Altman analysis

In a contemporary clinical laboratory it is very common to have to assess the agreement between two quantitative methods of measurement. The correct statistical approach to assess this degree of agreement is not obvious. Correlation and regression studies are frequently proposed. However, correlation studies the relationship between one variable and another, not the differences, and it is not r...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 40  شماره 1

صفحات  34- 39

تاریخ انتشار 2015-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.