Application of dual chamber microbial fuel cell with aeration cathode for bioelectricity generation and simultaneous industrial wastewater treatment

نویسندگان

  • Aghapour, Ali Ahmad Environmental Health Engineering, School of Public Health, Urmia University of Medical Sciences, Urmia, Iran
  • Navidjouy, Nahid Environmental Health Engineering, School of Public Health, Urmia University of Medical Sciences, Urmia, Iran
  • Rahimnejad, Mostafa Department of Chemical Engineering, Faculty of Chemical Engineering, Noshirvan University of Technology, Babol, Iran
  • Rashadi, Farah Environmental Health Engineering, School of Public Health, Urmia University of Medical Sciences, Urmia, Iran
چکیده مقاله:

Background and Objective: Microbial fuel cell (MFC) is a new green technology that uses the catabolic ability of microorganisms to produce bioenergy while simultaneously removing organic matter and other wastewater contaminants. Electrode material is one of the factors affecting the performance of microbial fuel cells. The aim of this study was to investigate the performance of microbial fuel cells in COD removal and bioenergy production from synthetic and real beverage wastewater. Materials and Methods: In this research, a two-chamber microbial fuel cell with Nafion membrane and aerated  cathode was set up using two electrodes made of carbon felt and flat graphite after being contacted by synthetic wastewater with a concentration of COD 5000  mg/L and real beverage wastewater. Organic matter removal efficiency and voltage, power density and maximum current were determine. Results: Experimental results showed that maximum COD removal efficiency of 92 % was achieved in synthetic wastewater and with a carbon felts electrode. In this condition, maximum voltage, power density and output current density of 469 mV, 175.28 mW/m2, and 855 mA/m2, were obtained, respectively. However, by using real industrial wastewater (beverage), maximum removal efficiency of COD, voltage, power density and output current density, related to carbon felt electrodes ‎were obtaines as 84 %, ‎460 mV, 91/65 mW/m2, and 635 mA/m2, respectively. Conclusion: The findings showed that synthetic wastewater outperforms microbial fuel cells in terms of bioelectric production and organic matter removal as compared to real wastewater (beverage). The reason for the decrease in the cell performance might be the presence of solids and other confounding pollutants in real wastewater.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient decolorization of real dye wastewater and bioelectricity generation using a novel single chamber biocathode-microbial fuel cell.

Large scale applications of microbial fuel cells (MFCs) have been severely hindered by several problems such as high internal resistance, low power output, expensive materials, and complicated configuration. To address these issues, a granular activated carbon based single chamber microbial fuel cell (GACB-SCMFC) has been designed using GAC-biocathodes without using any expensive materials for ...

متن کامل

dairy wastewater treatment and simultaneous electricity generation using microbial fuel cell technology

introduction population growth, increasing consumption of natural energy sources, the increasing use of fossil fuels, especially the oil and gas industry in recent years with the energy imbalance management has led to emergence of global energy crisis. moreover, rapid urbanization and industrialization have substantially increased the amount of high-strength wastewater being produced, which in ...

متن کامل

Microbial fuel cell performance with a pressurized cathode chamber.

Microbial fuel cell (MFC) power densities are often constrained by the oxygen reduction reaction rate on the cathode electrode. One important factor for this is the normally low solubility of oxygen in the aqueous cathode solution, which creates mass transport limitation and hinders oxygen reduction at the electrocatalyst (platinum, Pt). Here, we increased the air pressure in the cathode chambe...

متن کامل

Simultaneous electricity generation and sulfide removal via a dual chamber microbial fuel cell

 Transfer of produced electrons to anode is one of the main parts in MFCs.  Some MFCs needs artificial electron acceptors in their aerobic cathode compartment.  Cyclic voltammetry was used to study of anodic electrochemistry analysis.  Hexacyanoferrate was used as cathodic solution in different concentrations.  Maximum generated voltage and power density were 988.9145 mV, 346.746 mW.m, res...

متن کامل

Treatment of Domestic Wastewater with Simultaneous Electricity Generation in Microbial Fuel Cell under Continuous Operation

In order to apply microbial fuel cell (MFC) process more practically in wastewater treatment, both power generation and removal of chemical oxygen demand (COD) were examined in an air-cathode MFC fed with domestic wastewater under continuous operation. At a hydraulic retention time (HRT) of 2.0 h, the air-cathode MFC was able to generate electricity from domestic wastewater with a maximum power...

متن کامل

Comparison of anodic metabolisms in bioelectricity production during treatment of dairy wastewater in Microbial Fuel Cell.

Energy generation from dairy industry wastewater was investigated using a dual chambered Microbial Fuel Cell by aerobic and anaerobic anodic metabolism, operating with initial COD concentration of 1600 mg/L and anolyte pH of 7 produced highest power density of 192, 161 mW/m(2) and volumetric power of 3.2, 2.7 W/m(3) with COD removal efficiency of 91% and 90%, respectively. The columbic efficien...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 14  شماره 3

صفحات  473- 486

تاریخ انتشار 2021-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023