Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

نویسندگان

  • Abolfzal Nickfarjam Medical Physics Department, faculty of medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Radiotherapy Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran;
  • Daniel Markel Radiation Medicine Program, Princess Margaret Cancer Centre, University of Health Network
  • Mahdieh Afkhami Ardakani Department of Radiology, faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare- Abbas, Iran
  • Milad Najafzadeh Department of Radiology, faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare- Abbas, Iran
  • Mohammad Haghparast Department of Radiology, faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandare- Abbas, Iran
  • Mojtaba Hoseini-Ghahfarokhi Department of Radiology and Nuclear Medicine, School of Para Medical Sciences, Kermanshah University of Medical Sciences, Kermanshah, Iran
چکیده مقاله:

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by Siemens Oncor® linac’s head and DOSXYZnrc code utilized for calculating dose distributions in a virtual water phantom. The simulations were started for 10×10 cm2 and 40×40 cm2 field sizes. First the electron energy was changed to match percent depth dose curves of simulations with those of measurements. Second the beam width of primary electron source was tweaked to match between dose profile curves of simulation with those of measurement. For data comparison a 1-dimensional Gamma analyses were used with criteria of 3%/ 3mm using an inhouse-matlab script. The gamma analyses were performed while dose distributions of Monte Carlo and measurements were set as an evaluated and reference dose.   Results: The results of gamma analyses showed that for percent depth dose curves a passing rate of close to 100% evaluated points. Also for profile curves, the passing rates were above 95% of evaluated points. Therefore, all depth dose and dose profile curves were in good agreement. The agreements were found at 5.75 MeV primary electron and 0.35 cm beam width respectively.   Conclusion: The Monte Carlo model of 6 MV photon beam produced by Siemens Oncor® linear accelerator was accurately benchmarked using measured data. Since the profile curves of large field sizes are much more sensitive to the variations of beam width than small field size, it is recommended that for tuning process both field sizes are considered.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

A Monte Carlo Simulation of Photon Beam Generated by a Linear Accelerator

ntroduction:  Monte  Carlo  simulation  is  the  most  accurate  method  of  simulating  radiation  transport  and  predicting doses at different points of interest in radiotherapy. A great advantage of the Monte Carlo method  compared  to  the  deterministic  methods  is  the  ability  to  deal  accurately  with  any  complex  geometry.  Its  disadvantage is the extremely long computing time r...

متن کامل

Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam

Background: The electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. The detailed characteristics of contaminant electrons are presented for different field sizes and cases. Materials and Methods: The Monte Carlo code, MCNPX, has been used to simulate 18 MV photon beam from a Varian Linac-2300 accelerator. All dose measurements were car...

متن کامل

Localization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

متن کامل

monte carlo simulation of a linear accelerator and electron beam parameters used in radiotherapy

introduction: in recent decades, several monte carlo codes have been introduced for research and medical applications. these methods provide both accurate and detailed calculation of particle transport from linear accelerators. the main drawback of monte carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator

Purpose A Monte Carlo model of a 6 MV medical linear accelerator (linac) unit built indigenously was developed using the BEAMnrc user code of the EGSnrc code system. The model was benchmarked against the measurements. Monte Carlo simulations were carried out for different incident electron beam parameters in the study. Materials and Methods Simulation of indigenously developed linac unit has ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  394- 394

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023