Breast Radiation Protection in Coronary Angiography

نویسندگان

  • Ali Tarighatnia Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Mohammad Yousefi Sooteh Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Parinaz Mehnati Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Reza Malekzadeh Medical Radiation Sciences Research Team, Tabriz University of Medical Sciences, Tabriz, Iran Student research committee, Tabriz University of Medical Sciences, Tabriz, Iran
  • Yagub Khalegi Fard Tabriz Valiasr Hospital, Radiology and CT Scan Department, Tabriz, Iran
چکیده مقاله:

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In order to breast radiation protection in coronary angiography, the use of bismuth composite shield is a selective method. The purpose of this study was to evaluate the effectiveness of new bismuth composite shield to reduce the amount of received dose to the breast in coronary angiography. Method and Materials: The standard female phantom and Siemens angiography system used in this research. All the procedures were carried out by one operator because factors such as the operator’s skill and experience may affect on the patient radiation exposure. The bismuth composite shields were placed on the foam with thickness of 1 cm, exactly on the back of the phantom. Dose measurements were conducted by using three thermo luminescence dosimeters (TLDs) over each breasts location with and without using bismuth shield. Results: Breast dose was 2.45 mSv without using shield. After applying the bismuth composite shields, the recorded dose was changed to between 2.15 to 2.22 mSv. Therefore, the use of shields causes 10 % - 12% dose decline of sensitive breast tissue with acceptable imaging. Conclusion: The results showed that the use of bismuth composite shields in the coronary angiography, leads to an acceptable decrease in breast received dose.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary angiography with synchrotron radiation

Hamburger Synchrotron-Strahlungslabor, H A S Y M at DESY, Notkestr. 85,22607 Hamburg, Germany * Fachbereich 7 Physik &r Universitat Gesamthochschule Siegen, Adolf-Reichwein-Str. 2 , 57068 Siegen, Germany ** Kardiologische Abteilung der Medizinischen Klinik, Universitats-Krankt.nhaus Eppendoif, Martinistr. 52,20251 Hamburg, Germany *** Herz-Kreislauf-Klinik, Romstedter Str. 25,29549 Bad Bevensen...

متن کامل

Asymmetric breast dose in coronary angiography

The purpose of this study was to demonstrate asymmetric radiation dose distribution to the breasts in coronary angiography. Gafchromic XR-QA2 film was used as an area dosimeter to capture the asymmetric dose distribution to the breasts at various tissue depths in an anthropomorphic phantom. A selection of tube angulations were used under a controlled experiment and during a mock coronary angiog...

متن کامل

Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography.

BACKGROUND Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated. METHODS Radiation doses from CCTA to critical organs...

متن کامل

The role of quantitative feedback in coronary angiography radiation reduction.

OBJECTIVE To evaluate the benefits of radiation education with and without feedback reporting in altering clinician radiation use behaviour in performing coronary angiography (CA). DESIGN A retrospective review of radiation use (fluoroscopy time) in coronary angiograms performed between July 1996 and December 2005 by 10 cardiologists to assess the impact of various interventions aimed at mini...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  44- 44

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023