Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

نویسندگان: ثبت نشده
چکیده مقاله:

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Results Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m3)/(track/cm2) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m3). With replacing the skin instead of CR-39, the volume affected by Radon and progeny was determined to be 2.51 mm3 for one m2 of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m3). Conclusion Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m3).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

calculating cr-39 response to radon in water using monte carlo simulation

introduction cr-39 detectors are widely used for radon and progeny measurement in the air. in this paper, using the monte carlo simulation, the possibility of using the cr-39 for direct measurement of radon and progeny in water is investigated. materials and methods assuming the random position and angle of alpha particle emitted by radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector.

There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

Investigating Indoor Radon Concentration Using CR-39 Detector; a Case Study of Gachin Dwellings in Hormozgan

Introduction: Radon is a colorless inert gas which decay products are the main component of natural radioactive elements that are naturally produced in under layers of earth crust by decay of radium and uranium. It enters through buildings via gaps and cracks. Radon gas decay products like alpha particle can increase the incidence of lung cancer in human. Since every person sp...

متن کامل

Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data

Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...

متن کامل

experimental and monte carlo studies on the response of cr-39 detectors to am-be neutron spectrum

background: the poly-allyl diglycol carbonate (padc) detector is of particular interest for development of a fast neutron dosimeter. fast neutrons interact with the constituents of the cr-39 detector and produce h, c and o recoils, as well as (n, α) reaction. these neutron- induced charged particles contribute towards the response of cr-39 detectors. material and methods: electrochemical etchin...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 3

صفحات  193- 201

تاریخ انتشار 2012-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023