Calculation the phantom scatter factor for the linear accelerators device

نویسندگان

  • Ahmad Mostaar Medical Physics and Biomedical Engineering Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Ghazaleh Sadrieh Khajoo Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Mahdi Salehi Barough Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
  • Mohammad Ali Ostadrahimi Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran
چکیده مقاله:

Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on the scene of the phantom scattering factor. Materials and Methods: In this study, the MCNPX calculation code was used to simulate the Siemens linear accelerators to determine the measure of phantom scatter factor. The studied fields were chosen in this study with dimension 3×3, 10×10 and 20×20 cm2. It was also simulated to examine dosimetry parameters including deep dose curves and dose distribution for 6 and 15 MeV, a water phantom at SSD=100 cm in order to measure the phantom scattering factor and a total scatter factor and a build-up cap in order to measure the collimator scatter factor at SAD=100 cm.   Results: For field sizes 3×3 cm2 with 6 MV photon beams, the phantom scatter factor 0.9398, collimator scatter factor 0.8907 and the total scatter factor 0.8366, and also for the field sizes 20×20 cm2 with 6 MV photon beams, the phantom scatter factor 1.023, collimator scatter factor 1.0259 and the total scatter factor 1.0492 were calculated from monte carlo simulation. The Experimental values are equal to this 0.9398×0.8907=0.8370 for field sizes 3×3 cm2 and 1.023×1.0259=1.0494 for field sizes 20×20 cm2. All of the above values are normalized to field sizes 10×10 cm2 in 6 MV photon beams.   Conclusion: Due to the results obtained, the sensitive volume of the ion chamber is affected by the smaller than 10×10 cm2. It has also obtained phantom scattering factor independently and verified with the S(c,p) = Sc × Sp relation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators

INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...

متن کامل

New electrical device for field coincidence quality control test in linear accelerators

Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...

متن کامل

[Estimation of the phantom scatter factor (Sp) of rectangular fields].

This study proposes a method to accurately estimate the phantom scatter factor (Sp) of arbitrary rectangular fields. We measured output doses in water and air; these measured values were based on square fields and a limited number of symmetric rectangular fields using 4 MV and 10 MV X-rays of a Varian Clinac-iX. We calculated Sp from these measured values. Then, using these Sp values, we estima...

متن کامل

factor influencing the adoption of internet banking

دوره مشترک کارشناسی ارشد بازاریابی و تجارت الکترونیک دانشگاه تربیت مدرس_ دانشگاه تکنولوژی lule? چکیده پایان نامه عوامل موثر بر پذیرش اینترنت بانک توسط مشتریان پیشرفت فناوری اطلاعات و ارتباطات و به طور خاص رشد اینترنت جهت تراکنش های معاملات بازرگانی، تاثیر بسیار عمیقی در صنعت بانکداری داشته است.این در حالی ست که نفوذ بانکداری اینترنتی در کشورهای در حال توسعه بسیار کندتر از نفوذ آن ...

15 صفحه اول

the algorithm for solving the inverse numerical range problem

برد عددی ماتریس مربعی a را با w(a) نشان داده و به این صورت تعریف می کنیم w(a)={x8ax:x ?s1} ، که در آن s1 گوی واحد است. در سال 2009، راسل کاردن مساله برد عددی معکوس را به این صورت مطرح کرده است : برای نقطه z?w(a)، بردار x?s1 را به گونه ای می یابیم که z=x*ax، در این پایان نامه ، الگوریتمی برای حل مساله برد عددی معکوس ارانه می دهیم.

15 صفحه اول

the search for the self in becketts theatre: waiting for godot and endgame

this thesis is based upon the works of samuel beckett. one of the greatest writers of contemporary literature. here, i have tried to focus on one of the main themes in becketts works: the search for the real "me" or the real self, which is not only a problem to be solved for beckett man but also for each of us. i have tried to show becketts techniques in approaching this unattainable goal, base...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  277- 277

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023