Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging

نویسندگان

  • A Hashemi
  • B Rahimi
  • M Noroozi
  • N Valizadeh
  • S Hejazi
  • Sh Nateghi
  • V Alinejad
چکیده مقاله:

Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magnetic Resonance Imaging (MRI) is a safe, noninvasive, and accurate method for the assessment of iron deposition in different tissues. This study assessed iron levels in liver and heart of the patients with transfusion dependent hemoglobinopathies. Materials and Methods The studied population consisted of 12 patients (7 male and 5 female) with transfusion dependent hemoglobinopathies, aged between 10-18 years old. Then, Cardiac and liver T2*-weighted magnetic resonance imaging (MRI) were obtained. Results In current study, 1patient (8.33%) had severe, 2 patients (16.66%) had moderate and 2(16.66%) had mild cardiac iron deposition. Out of 12 patients, 1 had severe iron deposition in liver (8.33%), 5(41.66%) and 4(33.33%) had moderate and mild hepatic iron deposition, respectively. Differences between Hepatic and cardiac iron levels were not significant between males and females (p>0.05). Conclusion Since cardiac and liver iron levels were higher than normal in most of the study group, checking ferritin level and liver function test and also echocardiography in shorter intervals (each 3 months) in involved group is suggested instead of checking routinely in 6 month intervals in patients with transfusion dependent hemoglobinopathies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

cardiac and hepatic t2*-weighted magnetic resonance imaging

abstract background iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. severe iron deposition in tissues leads to organ dysfunction. many organs can be affected such as heart, liver, and endocrine organs. cardiac failure and liver fibrosis are the consequent of iron overload in transfusion dependent hemoglobinopathy. magnetic re...

متن کامل

Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging in Transfusion Dependent Hemoglobinopathy in North West of Iran

BACKGROUND Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magnetic Resonance I...

متن کامل

T2-weighted cardiovascular magnetic resonance in acute cardiac disease

Cardiovascular magnetic resonance (CMR) using T2-weighted sequences can visualize myocardial edema. When compared to previous protocols, newer pulse sequences with substantially improved image quality have increased its clinical utility. The assessment of myocardial edema provides useful incremental diagnostic and prognostic information in a variety of clinical settings associated with acute my...

متن کامل

assessment of cerebral venous sinus ‎thrombosis using t2*-weighted ‎gradient echo magnetic resonance ‎imaging sequences

background: the purpose of this study is to demonstrate the advantages of gradient echo (gre) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences. methods: a total of 17 patients with cerebral venous thrombosis (cvt) were evaluated using different magnetic resonance imaging (mri) sequences. the mri sequences i...

متن کامل

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 4

صفحات  206- 210

تاریخ انتشار 2015-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023