Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

نویسندگان

  • Hesameddin Akbarein Department of Food Hygiene and Quality Control, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
  • Maysam Tehranisharif Department of Pathobiology, Faculty of Veterinary Medicine, Islamic Azad University, Garmsar Branch, Garmsar, Iran
  • Shahram Jamshidi Department of Internal Medicine, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
  • Sina Jahan Department of Internal Medicine, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
چکیده مقاله:

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-owned dogs with various signalment and disease were included. Venous blood samples were obtained from a peripheral vein of each dog and blood glucose was measured with the three PBGMs. Immediately afterward, serum was harvested and sent to laboratory until analysis with reference methods. RESULTS: Blood glucose measured with the reference method was 21 to 650 mg/dl. There was a significant correlation between results of the reference method and PBGMs. Both of the veterinary specific PBGMs showed significant proportional and constant bias, nevertheless, no proportional and constant bias were recorded for human-based one. Mean deviation from reference methods was -7.4, 9.8, and -3.9 for AlphaTRAK2, CERA-PET, and Bionime respectively.  Although most of the PBGMs readings lay in the calculated 95% limits of agreement, none of the devices completely satisfied the International Organization for Standardization (ISO 15197:2013) criteria. Error grid analysis revealed all measurements for AlphaTRAK2 in zone A and B, while CERA-PET demonstrates one measurement in zone D. Bionime showed two  measurements in zone C and D. CONCLUSIONS: Only the result of AlphaTRAK2 could be interpreted without any hazardous outcome on medical decision making.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats

This study evaluated the accuracy of a newly developed veterinary portable blood glucose meter (PBGM) with hematocrit correction in dogs and cats. Sixty-one dogs and 31 cats were used for the current study. Blood samples were obtained from each dog and cat one to six times. Acceptable results were obtained in error grid analysis between PBGM and reference method values (glucose oxidation method...

متن کامل

comparison of blood glucose values using two glucose meters and standard laboratory method in hospitalized patients in a teaching hospital

background : diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. quality of blood glucose monitoring utilizing glucometers in iranian hospitalized patients has not been well published in the literature. we evaluated the accuracy and consistency of the results of two devices compared with the standard l...

متن کامل

ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a qu...

متن کامل

Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

BACKGROUND Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydro...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  187- 198

تاریخ انتشار 2019-05-22

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023