Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

نویسندگان

  • Neeraj Rao Department of Pediatrics, G.S.V.M Medical College, Kanpur
  • Tanu Midha Department of Preventive and Social Medicine, Government Medical College, Kannauj
چکیده مقاله:

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducted to evaluate the correlation of central venous pressure with IVC-CIand establish the cut off valuesfor IVC-CI to diagnose and manage neonatal shock.Methods: The current research was a prospective longitudinal study.All sick neonates requiring intensive hemodynamic monitoring were enrolled in the study and umbilical vein catheterization was performedto measure CVP. IVC diameters and IVC-CI were measured using ultrasound. Based on CVP, the patients were classified into three categories: hypovolemic (CVP<5 cmH2O), euvolemic (CVP 5-8 cmH2O), and hypervolemic (CVP>8 cmH2O) and managed with intravenous fluid boluses and/or inotropes, accordingly. CVP and IVC-CI were again recorded after the intervention and compared with the previous values.Results: A total of 76(62.3%) males and 46 (37.7%) females were included in the study with a mean age of 27.16±17.5 years. There was a strong negative correlation,which was statistically significant, between CVP and IVC-CI (r= -0.913, n=122, P<0.001). After luid resuscitation in the hypovolemic group, CVP improved from 2.31±0.92 to 5.88±1.79 cmH2O and IVC-CI changed from 62.39±6.005 to 33.02±2.64% which was statistically signi icant(P<0.001). After the administration of inotropes in the hypervolemic group, CVP dropped from 10.86±9.07 to 9.07±1.85cmH2O and IVC-CI changed from 11.27±4.71 to 24.3±13.3% which was again statistically signi icant(P<0.001). The receiver operator characteristic (ROC) curve analysis indicated that the IVC-CI cut-off of 55% predicted CVP <5 cmH2O with 87.9% sensitivity, 82% speci icity, 75.3%positive predictive value and 58.9% negative predictive value. IVC-CI cut-off of 20% predicted CVP >8 cmH2O with 91.1% sensitivity, 83.2% speci icity, 71.8% positive predictive value and 50.6% negative predictive value.Conclusion: The obtained results revealed an inverse correlation between CVP and IVC-CI, and it was concluded that IVC-CI can provide a useful guide in the diagnosis and management of shock in sick newborns.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

correlation between central venous pressure and inferior vena cava sonographic diameter; determining the best anatomic location

introduction: the correlation of central venous pressure (cvp) with inferior vena cava (ivc) sonographic diameter has been reported in several studies. however, few studies have attempted to find the best anatomic location of measurement. therefore, the purpose of this study was determining the best anatomic location to find precise correlation between cvp and ivc diameter using transesophageal...

متن کامل

Does a simple bedside sonographic measurement of the inferior vena cava correlate to central venous pressure?

BACKGROUND Bedside ultrasound has been suggested as a non-invasive modality to estimate central venous pressure (CVP). OBJECTIVE Evaluate a simple bedside ultrasound technique to measure the diameter of the inferior vena cava (IVC) and correlate to simultaneously measured CVP. Secondary comparisons include anatomic location, probe orientation, and phase of respiration. METHODS An unblinded ...

متن کامل

Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

INTRODUCTION The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal ...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

the role of russia in transmission of energy from central asia and caucuses to european union

پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره 3

صفحات  86- 91

تاریخ انتشار 2020-08-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023