Design of an Inhalation Chamber to Expose Laboratory Animals with Suspended Particulate Matter by Numerical Simulation Method

نویسندگان

  • Asilian-Mahabadi, Hassan Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
  • Bayareh, Morteza Department of Mechanical Engineering, Faculty of Engineering, Shahrekord University, Shahrekord, Iran
  • Rajabi-Vardanjani, Hassan Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
  • Sedehi, Morteza Department of Epidemiology and Biostatistics, School of Public Health, Shahrekord University of Medical Sciences, Shahrekord, Iran
چکیده مقاله:

Introduction: Usually, in the toxicological studies of airborne particulate pollutants, inhalation exposure chambers are used for providing and distributing the test atmosphere uniformly and stability in the respiratory zone of laboratory animals. The purpose of this study was to design, evaluate and optimize a whole-body exposure chamber, specifically for small laboratory animals exposed to particulate matter. Material and Methods: In the first, the papers and scientific resources which had provided the technical details and performance of the inhalation exposure chambers were studied, and the advantages, disadvantages and those factors affecting their performance were extracted. Then the assumptions of the initial design of the chamber were prepared with regard to the principles of fluid dynamics and the standard conditions of lab animal housing. To create a uniform distribution of particles inside the chamber, guide plates of flow were used in the upper cone. Numerical simulation and ANSYS Fluent software were used to optimize the initial design. Drawing geometry of the chambers was done using Design modeler software and meshing of the computational field using ANSYS meshing software. The particles used had a mean aerodynamic diameter of 10 μm, spherical, inert, and a density of 1,400 kg. m^-3 and entered the chamber at the carrier gas velocity. Particle concentration was measured in the chambers along the cylindrical radius at 10 cm intervals on the x-axis. Then the percentage of variation coefficient of the particle concentration for each line was calculated. In the final analysis of the results, the geometry design with the lowest coefficient of variation of particle concentration along the selected sampling line was selected as the best chamber design. Results: The optimized inhalation chamber has a dynamical flow and consists of a cylinder with two upper and lower cones. The flow enters from the upper cone and after passes through the guide plates, distributes in the interior of the chamber and exits from the lower cone. The k-ε turbulence and Discrete Phase Models could have modeled this problem. Design No. 7 was optimal design with the lowest coefficient of variation of the concentration (4.08%). Conclusion: The numerical simulation method for planning and optimizing of the chambers, at a much lower cost than the empirical methods, was able to provide comprehensive information on the solution field. The analysis of this information led to the selection of the best chamber design to provide uniform concentration of the particles in the respiratory region of the animals.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of copper binding by suspended particulate matter on toxicity.

The kinetics of Cu(II) interactions with Susquehanna River (mid-Atlantic, USA) particle suspensions using the copper ion selective electrode (Cu-ISE) method indicated that the concentration of Cu2+ in both the suspension and filtrate was kinetically controlled; the reaction of Cu(II) in the suspension was faster than that in the filtrate. Bioassay tests were performed in continuous flow-through...

متن کامل

Investigation of Suspended and Settled Particulate Matter in Indoor Air"

Particulate matter is a natural part of the atmosphere, where the solid or liquid particles are suspended in the air. These suspended particles, also known as suspended particulate matter represents a dispersion aerosol system. In the air there are many types of microscopic airborne particles originated from both natural and anthropogenic processes, such as atmospheric clouds of water droplets,...

متن کامل

The Trace Metal Geochemistry of Suspended Oceanic Particulate Matter

Vertical profiles of suspended particulate trace metals were measured in the Sargasso Sea near Bermuda and in the California Current, northwest Pacific. Using a new in situ pump, sufficiently large samples of particulate matter (order 10mg) were collected to allow measurement of a suite of trace metals as well as major component elements, using several different leaching techniques on separate ...

متن کامل

Determination of Total Suspended Particulate Matter and Heavy Metal

Corresponding Author: Muhammad Ali Awan, Institute of Environmental Science and Engineering (IESE), School of Civil and Environmental Engineering (SCEE), National University of Sciences and Technology (NUST12, Islamabad-44000, Pakistan. Tel: +92-51-90854305, E-mail: [email protected]. 128 Determination of Total Suspended Particulate Matter and Heavy Metals in Ambient Air of Four Cities of Pakistan

متن کامل

Total suspended particulate matter and daily mortality in Cincinnati, Ohio.

Recent studies have associated particulate air pollution with daily mortality in a number of U.S. communities. This study sought to replicate those analyses in Cincinnati, Ohio, and to test the strength of the association to the deletion of days with extreme weather conditions and to sensitivity analyses in the analytical approach. This study demonstrates the use of graphical diagnostic procedu...

متن کامل

Suspended Particulate Matter Transport through the Vema Channel

Sixteen-month time-series measurements of water velocity and light scattering were coupled with hydrographic and suspended particulate matter sections to determine the flux and the variability in flux of suspended particulate matter through the Vema Channel. The northward flux of SPM through the Vema Channel ranged from 3 to 10.5 × 104 g s 1 with a mean of 6.5 × 104 g s 1. The largest fluxes we...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 4

صفحات  346- 362

تاریخ انتشار 2019-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023