  Determination of the total body absorbed dose consists of two parts: Beta radiation absorbed dose and gamma radiation absorbed dose. The first part is generally determined by clinical data, while the second part has a parameter called absorbed ratio and is determined by computational methods. The Monte-Carlo computational methods have been shown to be the most suitable in determination of the absorbed dose ratio. We employed the Monte-Carlo code MCNP-4A and calculated the absorbed ratio for the whole body and thyroid gland. We used a distributed source of I-131 and calculated the absorbed ratio for emitted photons in different energies from this source. The phantom was an ellipsoid having the human body dimension. Water and material similar to body tissue were chosen as the phantom’s filling materials. Results of calculation were compared with Brownell works and the differences were acceptable. To check the accuracy of calculation, the phantom was divided into 5×5×5 cm cells and a complete symmetry in the absorbed dose within phantom was observed. The MCNP relative error was reduced to less than 1% by choosing more than 50,000 histories and applying variance reduction techniques.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of absorbed ratio in i-131 dosimetry using mcnp-4a [persian]

determination of the total body absorbed dose consists of two parts: beta radiation absorbed dose and gamma radiation absorbed dose. the first part is generally determined by clinical data, while the second part has a parameter called absorbed ratio and is determined by computational methods. the monte-carlo computational methods have been shown to be the most suitable in determination of the a...

متن کامل

Comparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom

Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...

متن کامل

SELIMETRY—a multicentre I-131 dosimetry trial: a clinical perspective

Treatment options for patients with thyroid cancer that is no longer sensitive to iodine therapy are limited. Those treatments which currently exist are associated with significant toxicity. The SELIMETRY trial (EudraCT No 2015-002269-47) aims to investigate the role of the MEK inhibitor Selumetinib in resensitizing advanced iodine refractory differentiated thyroid cancer to radioiodine therapy...

متن کامل

Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols.

For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ioniz...

متن کامل

Retrospective analysis of I-131 therapy in patients with follicular carcinoma of the thyroid [Persian]

In research institute for nuclear medicine (Tehran University of Medical Sciences) 50 patients with follicular thyroid carcinoma were evaluted retrospectively. The purpose of the study was assesment of the response of iodine-131 therapy. The best result were achieved when the patient treated with iodine-131 for the first time, in the 4th decade of life, with total thyroidectomy and no met...

متن کامل

Comparison and evaluation of value of thymoglobulin level in serum and I-131 whole body scan (I-131 WBS) in patients with differentiated thyroid carcinoma [Persian]

  This study was done in research institute of nuclear medicine from 1988-1992 for evaluation of the value of serum thyroglobulin level in comparison with 1-131 whole body scan (1-131 WBS) in patients with differentiated thyroid carcinoma. 204 patients who had total or near total thyroidectomy treated with 1-131 were evaluated in this study. Out of 204 patients 136 di...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره 2

صفحات  1- 6

تاریخ انتشار 2003-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023