Determination of Acetaminophen Via TiO2/MWCNT Modified Electrode

نویسندگان

  • Ali Asghar Pasban Refining Technology Development Division, Research Institute of Petroleum Industry, Tehran, Iran
  • Elham Hossein Nia Department of Chemistry, Faculty of Science, Karaj Branch, Islamic Azad University, Karaj, Iran
  • Masoumeh Piryaei Department of Biology, Faculty of Science, Payam Nour University, Tehran, Iran
چکیده مقاله:

Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM acetaminophen. The detection limit for the detection of acetaminophen was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of acetaminophen in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2% for five determinations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanostructured Modified Electrode for Electrocatalytic Determination of Epinephrine in the Presence of Acetaminophen

In this paper, a nanostructured modified electrode was fabricated by incorporating of 2,2′-[1,9-nonanediylbis(nitriloethylidyne)]-bis-hydroquinone (NNH) as a newly synthesized modifier and TiO2 nanoparticles to the carbon paste (MTCPE) and then was used for the electroanalysis of epinephrine (EP). The electrochemical studies were carried out by using cyclic voltammetry, chronoamperom...

متن کامل

Sensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode

This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was  performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...

متن کامل

nanostructured modified electrode for electrocatalytic determination of epinephrine in the presence of acetaminophen

in this paper, a nanostructured modified electrode was fabricated by incorporating of 2,2′-[1,9-nonanediylbis(nitriloethylidyne)]-bis-hydroquinone (nnh) as a newly synthesized modifier and tio2 nanoparticles to the carbon paste (mtcpe) and then was used for the electroanalysis of epinephrine (ep). the electrochemical studies were carried out by using cyclic voltammetry, chronoamperometry and di...

متن کامل

sensitive voltammetric determination of acetaminophen at poly(4-vinyl pyridine)/graphene composite modified electrode

this study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (ac). this was  performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (p4vp/gr-gce). the redox peak currents of ac increased significantly at p4vp/gr-gce. the result was achieved by the synergistic effect of combined elect...

متن کامل

Development of glassy carbon electrode modified with ruthenium red-multiwalled carbon nanotubes for simultaneous determination of epinephrine and acetaminophen.

A glassy carbon electrode modified with ruthenium red and functionalized multi-walled carbon nanotube has been developed. The electrochemical response characteristics of the modified electrode toward epinephrine (EP) and acetaminophen (AC) was investigated by differential pulse voltammetry (DPV). Linear calibration plots were obtained over the range of 0.3 - 333.3 μM for both EP and AC with sen...

متن کامل

Glassy Carbon Electrode Modified with Poly(taurine)/tio2-graphene Composite Film for Determination of Acetaminophen and Caffeine

A novel electrochemical sensor poly(taurine)/TiO2-graphene nanocomposite modified glassy carbon electrode (PT/TiO2-Gr/GCE) was fabricated. This sensor was based on an electrochemically polymerized taurine layer on a TiO2-graphene modified glassy carbon electrode. The electrochemical behavior of acetaminophen and caffeine at the modified electrode was studied by cyclic voltammetry and differenti...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 2

صفحات  142- 149

تاریخ انتشار 2017-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023