Determination of Central Venous Pressure from Intraocular Pressure

نویسندگان

  • GR. Masoumi Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
  • H. Kamalipour Department of Anesthesiology, Shiraz University of Medical Sciences, Shiraz, Iran
  • MH. Roozitalab Department of Ophthalmology, Shiraz University of Medical Sciences, Shiraz, Iran
چکیده مقاله:

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as well as those with glaucoma or cardiac ejection fraction of less than 50% were excluded from the study. Results: A linear correlation was found between CVP and IOP (r = 0.66, p<0.001).  CVP can be easily derived by halving the IOP. Conclusion: The use of this very simple method, particularly in those health care centers where due to the lack of necessary equipment for accessing central veins, CVP measurement is not possible, may provide useful information to physicians.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of central venous pressure from intraocular pressure

background: in many clinical situations, knowledge of central venous pressure (cvp) is important.  measurement of cvp is not always possible.   objective: to determine if intraocular pressure (iop) can be used as an estimate for cvp.   methods: iop and cvp were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  those with carotid artery or jugular venous diseases a...

متن کامل

Intraocular Pressure Reduction Is Associated with Reduced Venous Pulsation Pressure

PURPOSE To explore whether alterations in intraocular pressure (IOP) affect vein pulsation properties using ophthalmodynamometric measures of vein pulsation pressure. PATIENTS AND METHODS Glaucoma patients had two retinal vein pulsation pressure (VPP) measurements from upper and lower hemiveins performed by ophthalmodynamometry at least 3 months apart. All subjects had VPP and IOP recorded at...

متن کامل

Influence of tissue pressure on central venous pressure/peripheral venous pressure correlation: An experimental report.

BACKGROUND Peripheral venous pressure (PVP) has been shown to correlate with central venous pressure (CVP) in a number of reports. Few studies, however, have explored the relationship between tissue pressure (TP) and PVP/CVP correlation. METHODS PVP and CVP were simultaneously recorded in a bench-top model of the venous circulation of the upper limb and in a single human volunteer after under...

متن کامل

Continual monitoring of intraocular pressure: effect of central venous pressure, respiration, and eye movements on continual recordings of intraocular pressure in the rabbit, dog, and man.

A new method has been devised for continual monitoring of intraocular pressure by radiotelemetry. The use of this instrument for monitoring intraocular pressure by a variety of ophthalmic conditions is described.

متن کامل

Intraocular pressure and central corneal thickness.

From the results of the Ocular Hypertension Treatment Study emerged the conclusion that ocular hypertensive subjects with thinner central corneal thickness (CCT) are at increased risk of developing glaucoma. Although possible underlying biases that could have led to this conclusion are still under investigation, there is an increasing interest in the scientific community to understand the poten...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 28  شماره 2

صفحات  72- 74

تاریخ انتشار 2015-10-28

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023