Diagnostic Value of Non-stress Test Interpreted by Smart Interpretive Software

نویسندگان

  • Einolah Hatami PhD Candidate of Computer Engineering and Artificial Intelligence, Department of Computer, School of Electrical and Computer Engineering, Branch of North Tehran, Islamic Azad University, Tehran, Iran
  • Mahboubeh Ghorbani MSc of Midwifery, Lecturer, Department of Midwifery, School of Nursing and Midwifery, North Khorasan University of Medical Sciences, Bojnord, Iran
  • Mahboubeh Tabatabayee Chehr MSc of Midwifery, Lecturer, Department of Midwifery, School of Nursing and Midwifery, North Khorasan University of Medical Sciences, Bojnord, Iran
  • Maryam Bagheri MSc of Midwifery, Lecturer, Department of Midwifery, School of Nursing and Midwifery, North Khorasan University of Medical Sciences, Bojnord, Iran
  • Sakineh Nazari MSc of Midwifery, Lecturer, Department of Midwifery, School of Nursing and Midwifery, North Khorasan University of Medical Sciences, Bojnord, Iran Ph.D student of Reproductive Health, Student Research Committee, School of Nursing & Midwifery. Shahid Beheshti University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Background and aim: Using appropriate methods for the assessment of fetal health including non-stress test during high-risk pregnancies due to possible placental insufficiency is of paramount importance. Due to complexity in medical decisions, using information systems is being increased to support complex medical decisions. We conducted this study to measure the diagnostic value of non-stress test interpreted by smart interpretive software. Materials and Methods: This study was carried out on 400 non-stress tests obtained from patients’ records regardless of the results of tests in Bent-Ul-Hoda Hospital, Bojnord, Iran. Then, to increase the accuracy of tests, they were interpreted by two specialists with Master’s degree in Midwifery. Finally, the tests were interpreted by the given software. The diagnostic test accuracy was measured using sensitivity and specificity of the software. Results: Out of 400 selected tests, experts interpreted 126 tests with reaction and 274 cases without reaction. The diagnostic accuracy, sensitivity, and specificity of the software were 92.45%, 94.07, and 88.40, respectively. Conclusion: According to the results, the use of this software for interpreting non-stress test results, reduce false- positive and false-negative diagnoses.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Value of Non Stress Test in Latent Phase of Labor and Maternal and Fetal Outcomes

PURPOSE The Non Stress Test (NST) is the one of the significant diagnostic fetal well being testes. The purpose of this study is to access diagnostic value of NST during latent phase of labor by considering maternal and neonatal outcomes. SUBJECTS This case study control study was performed on 450 healthy pregnant women with gestational age between 38-42 weeks in AL-Zahra teaching hospital in...

متن کامل

Smart Antenna Software Radio Test System

This paper covers the concept, architecture, development and demonstration of a Smart Antenna Software Radio Test System (SASRATS). SASRATS was designed and developed as a functional and flexible system to facilitate the field testing of space-time processing architectures and algorithms. It also facilitates the correlation between theoretical, simulated and measured performance. The SASRATS ar...

متن کامل

Predictive value and informational value of diagnostic test results.

If clinical quality assurance and cost-effectiveness of diagnostic testing are to be measured, some sort of measurement of the clinical value of a test result is needed. The predictive value of a test result is not a real measure of its clinical value, and, particularly, when used in the later stages of a diagnostic workup, it can be misleading. Using the same data that go into a calculation of...

متن کامل

Diagnostic Value of Mallampati Test in Supine and Sitting Positions with and without Phonation in Anesthesia

Background and purpose: Airway assessment is very important in anesthesia. The aim of this study was to determine the diagnostic value of Mallampati test indicators in supine and sitting positions with and without phonation in anesthesia candidate patients. Materials and methods: This cross-sectional descriptive study (diagnostic approach) was done in 200 adult patients ≥16 years, undergoing s...

متن کامل

Diagnostic value of Phalen's test and Nerve Conduction Velocity in Carpal Tunnel Syndrome

Introduction: Carpal tunnel syndrome (CTS) is a prevalent disorder in women 30 to 60 years old, which is due to compression of median nerve in hand wrist tunnel. As this syndrome is prevalent, diagnostic power of clinical tests are undefined and electrodiagnostic tests are not accessible widely. This study was conducted to determine the diagnostic power of Phalen's test in comparison with NCV. ...

متن کامل

Diagnostic value of the lymphocyte transformation test for non-IgE mediated food allergy

Methods We investigated 3 groups of patients for identifying the food hypersensitivity. 1. Group 60 patients with symptoms of irritable bowel syndrome (IBS) without a diagnosis of organic gastrointestinal disease. 2. Group 19 patients with atopic dermatitis, polysenzitization to inhalant, not to food allergens. 3. Group 6 infants (3-12 months old) with intestinal symptoms (bloody stool and abdo...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 3

صفحات  1384- 1389

تاریخ انتشار 2018-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023