Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

نویسندگان

  • Ãœ Kara
  • R Ghanbarnezhad Farshi
چکیده مقاله:

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes lids, parotid glands and thyroid of 64 patients in two imaging centers (A and B). Phantom dosimetry was performed by a cylindrical poly-methyl methacrylate (PMMA) head-size phantom and an ionization chamber for different exposure parameters. NewTom VGi and Planmeca Promax 3D CBCT scanners were used at centers A and B, respectively.Results: The mean ESD of the eyes, parotid glands and thyroid were 2.57, 2.33 and 0.28 mGy in center A, 0.35, 2.11 and 0.37 mGy in center B, respectively. ESD of the eyes revealed a significant difference in two centers; in center B, it was 86.4% lower than center A. In the phantom dosimetry, the measured doses of NewTom VGi were 2.63 and 2.08 mGy, respectively by changing field of view (FOV) size from 8×8 cm2 (height × diameter) to 6×6 cm2. For Planmeca Promax 3D, it ranged from 0.98 to 3.24 mGy depending on exposure parameters.Conclusion: There is a wide range of radiation doses dependent on the units, patients and selected scan parameters. Inappropriate selection of exposure settings, especially FOV size, can seriously increase patient dose.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cone-Beam Computed Tomography for Oral and Maxillofacial Imaging

The invention of computed tomography (CT) technique revolutionized diagnostic imaging. Compared to conventional X-ray imaging procedures, CT involves higher radiation doses. Recently, cone-beam CT (CBCT) specifically designed for maxillofacial imaging was introduced. CBCT technique is based on a cone-shaped X-ray beam centered on a twodimensional (2D) detector. The detector system performs one ...

متن کامل

Absorbed dose of sensitive organs in maxillofacial region by different radiographic techniques: Panoramic, Waters, Caldwell and cone-beam computed tomography

BACKGROUND AND AIM: Due to increasing use of X-rays in diagnosis and treatment of diseases, this study aimed to measure and compares the absorbed dose in a number of sensitive organs of head and neck in different radiographic techniques.METHODS: Thermoluminescence dosimeter (TLD) and a male equivalent RANDO phantom were used to measure the absorbed dose in organs. The dosimeters were set in cer...

متن کامل

detection of foreign bodies by spiral computed tomography and cone beam computed tomography in maxillofacial regions

background and aims. the imaging techniques commonly used for foreign body detection include plain radiography, xeroradiography, computed tomography (ct) scans, magnetic resonance imaging (mri) and ultrasonography. the aim of the present study was to compare cone-beam computed tomography (cbct) with conventional ct scan in determination of the exact location of a foreign body in the maxillofaci...

متن کامل

Pediatric Phantom Dosimetry of Kodak 9000 Cone-beam Computed Tomography.

PURPOSE The purpose of the study was to evaluate the radiation dose of the Kodak 9000 cone-beam computed tomography (CBCT) device for different anatomical areas using a pediatric phantom. METHODS Absorbed doses resulting from maxillary and mandibular region three by five cm CBCT volumes of an anthropomorphic 10-year-old child phantom were acquired using optical stimulated dosimetry. Equivalen...

متن کامل

Concrescence: Cone-Beam Computed Tomography Imaging Perspective

Concrescence is a form of twinning, formed by the confluence of cementum of two teeth at the root level. The diagnosis of concrescence has largely relied on the conventional 2D imaging. The 2D imaging has inherent limitations such as distortion and superimposition. Cone-Beam CT eliminates these limitations. The aim of this article was to describe a case of dental abnormality using Cone-Beam CT ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 1

صفحات  -

تاریخ انتشار 2019-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023