Dynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle

نویسندگان

  • Hassan Hajabdollahi Department of Mechanical Engineering, Vali-e-Asr University of Rafsanjan, Rafsanjan, Iran
  • Zahra Hosseini Department of Mechanical Engineering, Vali-e-Asr University of Rafsanjan, Rafsanjan, Iran
چکیده مقاله:

A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front reveals that unlike the thermal system such as heat exchanger and power plant, the objective functions are not conflicted in the optimum situation. The optimum solutions show that R407c is the best refrigerant in both thermodynamics and economics viewpoints with 9148.2 $/year as total annual cost and 6.12 for COP. The optimum result of R407c showed that the total annual cost improved by 50.74% and 8.68% in comparison with R134a and R22, respectively. Furthermore, COP improved 9.97% and 13.72% in R407c compared with R134a and R22, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle

For most of the last fifty years, refrigeration and heat pump systems have been based on cycles using a fluorocarbon as the working fluid. Hovvever, with the discovery that fluorocarbons may have a profoundly detrimental effect on the earth ·s atmosphere. it has become necessary to find a suitable replacement for a fluorocarbon based refrigeration cycle. Such a replacement must perform comparab...

متن کامل

Multi-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries

The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...

متن کامل

Multi-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries

The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...

متن کامل

Modeling And Validation Of A Multi-Evaporator Vapor Compression Cycle Subject To Non-Uniform Loading In Transport Refrigeration Applications

This paper describes a multi-evaporator vapor compression model capable of simulating the dynamic behaviour of transport refrigeration systems. A discrete multi-zone control volume approach is utilised for modelling the condenser and evaporators. All other major refrigeration components including compressor, expansion valves, receiver, pressure-regulating valves are modeled using time-dependent...

متن کامل

Parametric Study of a Vapor Compression Refrigeration Cycle Using a Two-Phase Constant Area Ejector

There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative ways. The present paper aims at evaluate the performance improvement of a vapor compression refrigeration cycle under a wide range of operating conditions. A numerical model is developed and a parametric study of important parameters suc...

متن کامل

Performance of High Pressure Air Cycle in Comparison With Synthetic and Natural Vapor Compression Refrigeration Cycles

Concerning the use of HFCs as substitutes for CFCs and HCFCs a major concern in applications with remarkable leakages of refrigerant is its contribution to global warming. Therefore, the attention has been drawn to the use of natural working fluids, like carbon dioxide, hydrocarbons, water and air. Air had been already used in the range of air conditioning technology. Air as refrigerants is sta...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 2

صفحات  153- 167

تاریخ انتشار 2020-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023