Effect of Impressed Current on Bond Strength Between Steel Rebar and Concrete

نویسنده

  • R. Dehghanian Elecrtical and Computer Enginnering, Isfahan University of Technology
چکیده مقاله:

The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a function of time and distance from the rebar. Bond strength and chemical analyses for cylinders exposed to the current flow were compared to those determined for the cylinders with no impressed current (control). After forty two months of experiment, it was found that the impressed current had weakened the bond between the rebar and concrete significantly. This weakening in some cases was a factor of two lower compared to the control cylinders of the same age. The concentration of sodium and potassium ions near the rebar for the test cylinders increased with exposure time to current. The chloride ions migrated toward the concrete surface as expected. The decrease in bond strength was probably due to the accumulation of sodium ions near the rebar. It is well known that high sodium concentration will attack the portland cement matrix. These results indicate that there should be some concern about the long term effects of cathodic protection for reinforcing concrete structures.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes

In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...

متن کامل

Bond of High Strength Concrete with High Strength Reinforcing Steel

This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...

متن کامل

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

CORROSION BEHAVIOR OF ZINC COATED STEEL REBAR IN HIGH-STRENGTH REINFORCED CONCRETE

A large number of reinforced concrete structures subjected to chloride ions. Two basicapproaches for preventing corrosion of reinforcing steel embedded in concrete are: Increasing theconsolidation of concrete and using different coating on rebars. In present research steel rebarsare coated in different ways: a) 40 µm of zinc electroplated on steel rebar b) Zinc powder withepoxy paste (zinc rich...

متن کامل

Evaluation of concrete-steel bond strength in wet mix sprayed concrete

The high performance obtained in wet mix sprayed concrete has extended the field of applications of this technique. In some of these applications, such as in diaphragm walls or bridge rehabilitation, the structure may be subjected to bending moments, so conventional reinforcement is regularly used. In this context it is important to assure adequate bond between steel rebar and the sprayed concr...

متن کامل

Effect of Reinforcing Bar Contamination on Steel-Concrete Bond During Concrete Construction

Synopsis: During concrete construction, form oil, bond breaker, concrete splatter and other types of contaminants often contaminate reinforcement. Current specifications and quality control measures require the removal and clean up of these contaminants before the placement of concrete due to a concern of a reduction in bonding capacity. This is costly, labor intensive, and may not be necessary...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره 3

صفحات  121- 134

تاریخ انتشار 1998-08-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023