Evaluation of deformable image registration in HDR gynecological brachytherapy

نویسندگان

  • Ramin Jaberi Department of Radiotherapy, Cancer Institute, Tehran University of Medical Science, Tehran, Iran
  • Reza Mohammadi Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran Medical Image and Signal Processing Research Core, Iran University of Medical Sciences, Tehran, Iran
  • Reza Reiazi Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran Medical Image and Signal Processing Research Core, Iran University of Medical Sciences, Tehran, Iran
  • Seyed Rabee Mahdavi Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from ICRU recommendation that propose add maximum doses to the volume of 2cc of every organ (D2cc) from every session. Especially for the OAR, it makes the safe conservative assumption that the same part of the OAR always receives the highest dose. The dose calculated this way often limits the prescription dose or the target coverage. In this work, we propose to investigate an alternative method to assess the cumulative dose for an HDR GYN treatment course; the use of image deformation software to track the deformations of the OAR from one fraction to the next. Materials and Methods: Thirty patients with locally advanced cervical cancer who had been treated by external beam radiotherapy (EBRT) and three to four fractions of HDR brachytherapy (HDR-BT) were introduced to this study. Intensity-based free form deformation algorithm has been used as the primary DIR techniques using MIM software. In the dose accumulationn stage, total doses of rectum and bladder from all brachytherapy fractions have been integrated by deformable image registration techniques. Results: The DICE, jaccard, MDA and HD indexes of deformable registration for bladder and rectum were (0.94±0.03), (0.89±0.06), (0.83±0.3), (9.85±3.8) and (0.86±0.05), (0.78±0.07), (1.46±0.7), (14.4±0.1) respectively compared to rigid registration for bladder and rectum that were (0.74±0.07), (0.61±0.07), (4.2±2.3), (18.73±8.6) and (0.59±0.13), (0.43±0.11), (5.01±1.7), (23.4±1.1) respectively. Dose accumulation of D2cc values were (5.1±2,3)% and (2.7±1.1)% lower for the bladder and rectum respectively compared to adding D2cc of each fractions. Conclusion: Using deformable image registration, based on image intensity, allows to accumulate the dose from different brachytherapy fractions. The results from our study indicate that it is feasible to utilize deformable image registration for dose accumulation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Deformable Image Registration

Deformable image registration (DIR) is a type of registration that calculates a deformable vector field (DVF) between two image data sets and permits contour and dose propagation. However the calculation of a DVF is considered an ill-posed problem, as there is no exact solution to a deformation problem, therefore all DVFs calculated contain errors. As a result it is important to evaluate and as...

متن کامل

Comparison of two planning systems for HDR brachytherapy gynecological application

PURPOSE This report compares the Nucletron NPS and PLATO planning system for patients treated for cervix cancer. MATERIALS AND METHODS This study compares calculations generated using the older NPS (version 11.43) planning system and the more recent PLATO (version 14.1) system for two cases: 1) a single dwell position and 2) an actual patient application using a tandem and ovoid. RESULTS Fo...

متن کامل

Evaluation of whole‐body MR to CT deformable image registration

Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based...

متن کامل

Evaluation of various deformable image registration algorithms for thoracic images

We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical lan...

متن کامل

Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation

Accurate prostate delineation is essential to ensure proper target coverage and normal-tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS-based prostate contour into HDR treatment planning through TRUS-CT deformable registration (TCDR) to improve prostate contour accuracy. In a perspective study of 16 patie...

متن کامل

Deformable Model-based Image Registration

Medical image analysis technology, with image segmentation, image matching /registration, motion tracking and the measurement of anatomical and physiological parameters as the main research areas, has seen a tremendous amount of growth over the past decade. The work described in this chapter is concerned with the problem of automatically aligning 3D medical images. Image registration is one of ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  222- 222

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023