Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

نویسندگان

  • Daneshian, Elahe Department of Radiation Technology, Shahid Sadoughi University of Medical Sciences, Yazd
  • Parach, Ali Asghar Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd
  • Asgari, Azam Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd
  • Nekoofar, Zahra Department of Radiation Technology, Shahid Sadoughi University of Medical Sciences, Yazd
چکیده مقاله:

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patients' dose. Various factors such as the use of thyroid collar, lead goggles, field size, device type, imaging parameters such as tube voltage and current, alternating or pulsed radiation; type, amount and shape of the filter, 360 degree or partial rotation of tube and scan time, can affect the absorbed dose of the patient in dental CT scans. Among these, the use of thyroid collar (42% reduction), lead goggles (6% reduction),the smallest possible field of view ( up to 90%), pulse irradiation, patient sitting position and 180o rotation angle instead of 360o (more than 50% reduction) cause significant reduction in the organ doses and effective dose of the patients. It should also be kept in mind that measures taken to reduce the patients' dose should not impair image quality and, depending on the patient's condition, the radiographer will select the dose reduction parameters without degrading the image quality.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

Cone beam CT for dental and maxillofacial imaging: dose matters.

The widespread use of cone-beam CT (CBCT) in dentistry has led to increasing concern regarding justification and optimisation of CBCT exposures. When used as a substitute to multidetector CT (MDCT), CBCT can lead to significant dose reduction; however, low-dose protocols of current-generation MDCTs show that there is an overlap between CBCT and MDCT doses. More importantly, although the 3D info...

متن کامل

[Comparison of absorbed and effective dose from two dental cone beam computed tomography scanners].

OBJECTIVE This research compared the field of view with the tissue absorbed dose and effective doses using the two dental cone beam computed tomography (CBCT) scanners. MATERIALS AND METHODS Two CBCT devices, an Alphard VEGA and 3DX multi-image micro CT MCT-1, were used. Measurements were made using an Alderson RANDO phantom and thermoluminescence dosimeters (TLDs). The calculation of the eff...

متن کامل

Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.

OBJECTIVE To estimate effective dose of cone beam CT (CBCT) of the facial skeleton with focus on measurement methods and scanning protocols. METHODS A systematic review, which adhered to the preferred reporting items for systematic reviews (PRISMA) Statement, of the literature up to April 2014 was conducted. Data sources included MEDLINE®, The Cochrane Library and Web of Science. A model was ...

متن کامل

optimization of parameters in 16-slice ct- scan protocols for reduction of the absorbed dose

introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...

متن کامل

Patient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 28  شماره 4

صفحات  2521- 2532

تاریخ انتشار 2020-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023