Evaluation of Metal Artifact Reduction software in Computed Tomography

نویسندگان

  • Eslam Maamoun Medical Imaging and Nuclear Medicine Department, Kundiawa Genaral Hospital, Papua New Guinea
چکیده مقاله:

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative reconstruction algorithm (IDREAM). Material and Methods: Water phantom with raw chicken leg underwent CT scan (Sinovision, Insitum 16) before (reference group (GPref) and after metal implantation: ((GPA (IDREAM without MAR) and GPB(IDREAM with MAR)).  A total number of 30 patients [GP1 (instrumented spine (n=15)), GP2 (Brain clips (n=15))] underwent CT scan (Sinovision ,Insitum 16). GP1 and GP2 were reconstructed using two procedures including IDREAM without MAR vs.  2: IDREAM with MAR. All images were evaluated using subjective and quantitative assessment. Results: In subjective image quality assessment, the scores of MAR images were higher than IDREAM images (P<0.05) as indicated by four radiologists. The absolute CT difference (ΔCT) and Artifact index (AI) demonstrated that MAR appeared to be superior for the reduction of metal artifacts (P<0.05). Conclusion: As evidenced by the obtained results, MAR software can be efficiently used for metal artifact reduction in computed tomography (instrumental spine and brain clips).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Edge–Preserving Metal Artifact Reduction in Computed Tomography

Esther Meyer1,2, Rainer Raupach2, Michael Lell3, Bernhard Schmidt2, and Marc Kachelrieß1,4 1Institute of Medical Physics, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany  2Siemens Healthcare, Forchheim, Germany 3Institute of Diagnostic Radiology, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany 4Medical Physics in Radiology, German Cance...

متن کامل

Frequency split metal artifact reduction (FSMAR) in computed tomography.

PURPOSE The problem of metal artifact reduction (MAR) is almost as old as the clinical use of computed tomography itself. When metal implants are present in the field of measurement, severe artifacts degrade the image quality and the diagnostic value of CT images. Up to now, no generally accepted solution to this issue has been found. In this work, a method based on a new MAR concept is present...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Defne Us Metal Artifact Reduction in Sinograms of Dental Computed Tomography

TAMPERE UNIVERSITY OF TECHNOLOGY International Master’s Degree Programme in Biomedical Engineering US, DEFNE: Metal Artifact Reduction in Sinograms of Dental Computed Tomography Master of Science Thesis, 70 pages, 4 Appendix pages May 2013 Major subject: Biomedical Engineering Examiners: Prof. Ulla Ruotsalainen Prof. Jari Viik M.Sc. Uygar Tuna

متن کامل

Quantitative Comparison of Commercial and Non-Commercial Metal Artifact Reduction Techniques in Computed Tomography

OBJECTIVES Typical streak artifacts known as metal artifacts occur in the presence of strongly attenuating materials in computed tomography (CT). Recently, vendors have started offering metal artifact reduction (MAR) techniques. In addition, a MAR technique called the metal deletion technique (MDT) is freely available and able to reduce metal artifacts using reconstructed images. Although a com...

متن کامل

Reduction of Metal Artifact in Single Photon-Counting Computed Tomography by Spectral-Driven Iterative Reconstruction Technique

PURPOSE The exciting prospect of Spectral CT (SCT) using photon-counting detectors (PCD) will lead to new techniques in computed tomography (CT) that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 17  شماره 5

صفحات  298- 302

تاریخ انتشار 2020-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023