Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index

نویسندگان

  • Elaheh Allahyary Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Faghihi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
  • Saman Asadi Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Faghihi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
  • Sayed Mohammad Reza Hadavi Anesthesiology and Critical Care Research Center, Department of Anesthesiology, Faghihi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
چکیده مقاله:

Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic technique in C/S.Methods: This study was carried out on 60 parturient patients undergoing elective C/S. A standardized anesthetic technique was applied: induction with Thiopental (4-5 mg/kg) and Succinylcholine (1.5-2 mg/kg) as well as maintenance with O2, N2O, and isoflurane. Electrocardiogram, heart rate, blood pressure, Spo2, end-tidal isoflurane concentration, BIS, and any clinical signs of inadequate depth of anesthesia such as movement, sweating, lacrimation, coughing, and jerking were continuously monitored and recorded at 16 fixed time points during anesthesia. Results: A median BIS of less than 70 (range: 42-68) was obtained on all occasions during surgery; however, at each milestone, at least 20% of the patients had BIS values above 60. Hemodynamic parameters increased significantly in some patients, especially during laryngoscopy and intubation. No patient experienced recall or awareness. Conclusion: The currently used general anesthetic technique in our center appears inadequate in some milestones to reliably produce BIS values less than 60, which are associated with lower risk of awareness. Therefore, with respect to such desirable outcomes as good Apgar and clinical status in neonates, we would recommend the application of this method (if confirmed by further studies) through larger dosages of anesthetic agents. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

evaluation of the adequacy of general anesthesia in cesarean section by bispectral index

background: awareness and recall, though not common, are the major hazards of general anesthesia, especially in cesarean section (c/s) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. in this study, the bispectral index (bis), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...

متن کامل

The effects of hyperbaric or isobaric bupivacaine on bispectral index in spinal anesthesia for cesarean section

BACKGROUND Hyperbaric and isobaric bupivacaine has been shown to reduce bispectral index (BIS) during spinal anesthesia. The aim of this study was to compare the effect of isobaric bupivacaine and hyperbaric bupivacaine on the BIS during cesarean section with spinal anesthesia. MATERIALS AND METHODS In this double-blind randomized controlled clinical trial, 84 pregnant women with ASA (America...

متن کامل

the effects of hyperbaric or isobaric bupivacaine on bispectral index in spinal anesthesia for cesarean section

background : hyperbaric and isobaric bupivacaine has been shown to reduce bispectral index (bis) during spinal anesthesia. the aim of this study was to compare the effect of isobaric bupivacaine and hyperbaric bupivacaine on the bis during cesarean section with spinal anesthesia. methods : in this double-blind randomized controlled clinical trial, 84 pregnant women with asa ( american society o...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 38  شماره 3

صفحات  240- 247

تاریخ انتشار 2013-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023