Exergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units

نویسندگان

  • Hossein Yousefi Department of Renewable Energy and Environment Faculty of New Sciences and Technologies, university of Tehran, Tehran, Iran
  • Kianoosh Choubineh Department of Renewable Energies and Environment, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
  • Tohid Jafarinejad Department of Energy Engineering, Sharif University of Technology, Tehran, Iran
چکیده مقاله:

Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A comprehensive methodology for exergetic analysis of vapor compression heating ventilation and air conditioning systems has been presented. The quasi-dynamic component-by-component exergy analyses of both the conventional and novel air dehumidification systems have been conducted for a specific outside air fraction. Also, sensitivity analyses have been conducted on the exergy destruction and efficiency as a function of outside air fraction. Results denote that for the outside air fraction of 53%, exergy destruction of the novel air dehumidification system has decreases up to 32.4% and exergy efficiency has ramped up by 53.45%. Moreover, by rising the outside air fraction from none to 100%, exergy destruction in the novel air dehumidification system has declined by 46% to 30.5 %, and exergy efficiency has undergone a 106% to 40.3 % increase compared with the conventional system depending on the outside.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

An Experimental Study of Nanofluids Operated Shell and Tube Heat Exchanger with Air Bubble Injection

Shell and Tube heat exchangers are the heat exchangers that are most widely used in industries and for other commercial purposes. There are many techniques that have been utilized to enhance the heat transfer performance of the shell and tube heat exchangers. Air bubble injection is one of the promising and inexpensive techniques that can create turbulence in the fluids resulting in to enhancem...

متن کامل

Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)

Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...

متن کامل

Numerical Analysis of Heat and Mass Transfer in a Fin-and-Tube Air Heat Exchanger under Full and Partial Dehumidification Conditions

Heat exchangers are commonly used in industrial fields such as air conditioning, petrochemical and agriculture-food industries. The design and utilization of a heat exchanger should fulfill some conditions of performance, economy and space requirement. The most widely operated heat exchangers make use of fin-and-tube configuration in association with the application of heating, ventilating, air...

متن کامل

Sensitivity analysis on the performance of a ground source heat pump equipped with a double U-pipe borehole heat exchanger

Ground Source Heat Pumps (GSHP) are economically and environmentally advantageous for the heating and cooling of buildings, provided that the long-term sustainability of the thermal exploitation of the soil is ensured. In particular, the performance of a closed-loop Borehole Heat Exchanger (BHE) strongly depends on the geometrical and physical properties of its components and on the thermo-hydr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 3

صفحات  215- 224

تاریخ انتشار 2019-08-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023