Feasibility evaluation of trace amount of zinc in urine samples using atomic absorption solidified floating organic drop micro-extraction technique

نویسندگان

  • Hossein Ali Rangkooy Departments of Occupational Health, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
  • Masoud Rismanchian Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran
  • Mitra Shabab Student Research Committee, Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Sara Karimi Zeverdegani Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran.
چکیده مقاله:

Background: The present study was carried out with the aim of extracting trace amounts of zinc in urine samples with ultrasound-assisted emulsification solidified floating organic drop micro-extraction (USAE-SFODME) method by flame atomic absorption spectrometry (FAAS). The efficiency was investigated using the solvent extraction volume, extraction pH, time sonication and temperature extraction. The present study was conducted aiming to respond on the efficiency of SFODME technique in extracting inorganic analytes in biological samples. Materials and Methods: This was an experimental research with several steps. After preparation standard solution of zinc, USAE-SFODME technique was used for extracting zinc cation from urine samples. This method involves centrifuge, buffer and ligand adding, sonication, extraction of analyte and finally analysis with FAAS. Excel 2010 software was used in this study in order to plot the graphs. Results: Extraction of zinc was performed under optimized conditions of 2 ml 1-(2-Pyridylazo)-2-naphthol (PAN), 90 µl 1-dodecanol, pH = 5.5, for 20 minutes at 35 ˚C. Recovery, the regression coefficient, and relative standard deviation (RSD) were obtained as 96.6% and 99.0%, respectively. RSD for tree concentration 0.8 µgml-1 Zn cation (Zn2+) was 3.4%. The limit of detection (LOD) was found to be 0.426 µgml-1. Conclusions: Using green solvents, downsizing the samples, replacement of toxic reagents use, and lack of needing the preparation of the samples are the most important advantages of this technique. USAE-SFODME has a successful development in determining trace amounts of zinc in urine samples which can be performed in chemical laboratories with rather ordinary equipment.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Solidified floating organic drop micro-extraction (SFODME) for simultaneous separation/pre-concentration and determination of cadmium by atomic absorption spectroscopy

43 Solidified floating organic drop micro-extraction (SFODME) for simultaneous separation/pre-concentration and determination of cadmium by atomic absorption spectroscopy R. Parviz, M. Honari Department of Chemistry, Faculty of Science, Islamic Azad University Shahr-E-Rey Branch, Shahr-E-Rey, Iran Department of Plant Breading and Biotechnology, Agriculture and Natural Resources Faculty, Tehran ...

متن کامل

Solidified Floating Organic Drop Microextraction for the Detection of Trace Amount of Lead in Various Samples by Electrothermal Atomic Absorption Spectrometry

A novel method was developed for determination of trace amounts of lead in water and food samples. Solidified floating organic drop microextraction was used to preconcentrate the lead ion. After the analyte was complexed with 1-(2-pyridylazo)-2-naphthol, undecanol and acetonitrile were added as extraction and dispersive solvent, respectively. Variables such as pH, volumes of extraction and disp...

متن کامل

dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

an efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (dllme-sfod), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. in this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Ultrasound-Assisted Emulsification Solidified Floating Organic Drop Microextraction for the Determination of Trace Cadmium in Water Samples by Flame Atomic Absorption Spectrometry

Uma técnica de microextração em fase líquida foi desenvolvida para a extração e determinação de quantidades traço de íons cádmio em amostras de água. A emulsificação-microextração assistida por ultrasom através da gota orgânica flutuante solidificada (USAE-SFODME) foi empregada para a extração e a espectrometria de absorção atômica com chama (FAAS) foi empregada para a determinação de Cd. Foram...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFOD), combined with flame atomic absorption spectrometry was developed for preconcentration and determination of trace amounts of cobalt in water samples. In this method, an appropriate mixture of acetone and 1-undecanol was injected rapidly into th...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 1

صفحات  11- 19

تاریخ انتشار 2018-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023