Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors

نویسندگان

  • Alisina Shahi The Rothman Institute at Thomas Jefferson University, Philadelphia, PA
  • James Krieg The Rothman Institute at Thomas Jefferson University, Philadelphia, PA
  • Javad Parvizi The Rothman Institute at Thomas Jefferson University, Philadelphia, PA
  • Jessica Viola The Rothman Institute at Thomas Jefferson University, Philadelphia, PA
  • Mohammad Rasouli The Rothman Institute at Thomas Jefferson University, Philadelphia, PA Sina Trauma and Surgery Research Center, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Background:  Little is known about trends and predictors of hardware related infection following open reduction and internal fixation (ORIF) of extremity fractures, one of the major causes of failure following ORIF. The present study was designed and conducted to determine trends and predictors of infection-related hardware removal following ORIF of extremities using a nationally representative database. Methods:  We used Nationwide Inpatient Sample data from 2002 to 2011 to identify cases of ORIF following upper and lower extremity fractures, as well as cases that underwent infection-related hardware removal following ORIF. Multivariate analysis was performed to identify independent predictors of infection-related hardware removal, controlling for patient demographics and comorbidities, hospital characteristics, site of fracture, and year.  Results:   For all ORIF procedures, the highest rate of hardware removal related to infection was observed in tarsal fractures (5.56%), followed by tibial (3.65%) and carpal (3.37%) fractures. Hardware removal rates due to infection increased in all fractures except radial/ulnar fractures. Tarsal fractures(odds ratio (OR)=1.06, 95% confidence interval (CI): 1.04-1.09, P

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

hardware removal due to infection after open reduction and internal fixation: trends and predictors

background:  little is known about trends and predictors of hardware related infection following open reduction and internal fixation (orif) of extremity fractures, one of the major causes of failure following orif. the present study was designed and conducted to determine trends and predictors of infection-related hardware removal following orif of extremities using a nationally representative...

متن کامل

Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors.

BACKGROUND Little is known about trends and predictors of hardware related infection following open reduction and internal fixation (ORIF) of extremity fractures, one of the major causes of failure following ORIF. The present study was designed and conducted to determine trends and predictors of infection-related hardware removal following ORIF of extremities using a nationally representative d...

متن کامل

The Outcomes of Pilon Fracture Treatment: Primary Open Reduction and Internal Fixation Versus Twostage Approach

Background: Pilon fracture is one of the challenging injuries in orthopedic surgery. Associated soft tissue injury is animportant factor in choosing treatment options. Two major methods of treatment are considered as one-stage openreduction internal fixation (ORIF) and two-stage treatment (primary external fixation and secondary ORIF). The latter ismost accepted in literature. In the current st...

متن کامل

Risk factors of wound infection after open reduction and internal fixation of calcaneal fractures

The aim of this study was to investigate the risk factors of wound infection after open reduction and internal fixation of calcaneal fractures.In all, 299 patients with 318 calcaneal fractures who underwent open reduction and internal fixation by a single surgeon were grouped according to different outcomes. We gathered the data on each patient including sex, age, injury mechanism, body mass in...

متن کامل

Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures

BACKGROUND AND PURPOSE In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. METHODS 5...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 3

صفحات  184- 192

تاریخ انتشار 2015-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023