In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

نویسندگان

  • Abbas Mohammadi Department of Radiology, Faculty of Dentistry, Oral and Dental Disease Research Center, Zahedan University of Medical Sciences, Zahedan, Iran
  • EshaghAli Saberi Oral and Dental Diseases Research Center and Department of Endodontics, Dental School, Zahedan University of Medical Sciences, Zahedan, Iran
  • Sediqe Ebrahimipour Department of endodontics, Faculty of Dentistry and Dental research center, Birjand University of Medical Sciences, Birjand, Iran
  • Sepideh Baniasadi General Dentist, Zahedan, Iran
چکیده مقاله:

Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having roots with previous cracks and defects were excluded from the study. The crowns and distal roots of teeth were cut. Silicon impression material was used to simulate tooth PDL. The mesial roots were randomly prepared using ProTaper (up to F3) RaCe and Niti Tee systems (up to ≠30/0.06) in three groups of 15. Five teeth remained unprepared as the control group. The specimens were then sectioned horizontally in 3, 5 and 9 mm distances from the apex. Cracks exploration was done by digital stereomicroscope. The occurrence of dentinal cracks with different systems were statistically analyzed by chi-square test. Results: Dentinal defects were observed in 3 (20%), 4 (26.7%) and 2 (13.3) of root canals following the preparation with ProTaper, Niti Tee and RaCe files, respectively. Two of the 3 defects in protaper group were as complete crack. The overall incidence of crack among the rotary files was 20%. No significant differences were found in defect formation between the three rotary systems (P>0.05).  Conclusion: Under the condituion of this study Dentinal cracks were observed in all systems. The overall incidence of crack among the rotary files was 20%. Although more cracks were observed in NTiTee group, the differences were not significant.    

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin.

INTRODUCTION The aim of the present study was to investigate the incidence of cracks in root dentin after root canal preparation with ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex (Coltene-Whaledent, Allstetten, Switzerland), and ProTaper Universal (Dentsply Maillefer) rotary instruments. METHODS One-hundred mandibular premolars were selected. Twenty-five teeth were left...

متن کامل

comparison of dentinal crack formation with reciproc, mtwo and protaper root canal preparation systems

conclusions regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. although there was more crack incidence in protaper files, no significant differences were noted regarding the studied systems and sections from the apex. materials and methods in an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their cro...

متن کامل

Cyclic Fatigue Resistance and Fractographic Analysis of Race and Protaper Rotary NiTi Instruments

INTRODUCTION This study investigated the fatigue and fracture modes of RaCe and ProTaper rotary instruments. MATERIALS AND METHODS Fatigue resistance was evaluated by rotating the files 30° or 60° and with 2 or 5mm radius of curvature. RaCe taper 06 size 25 and ProTaper F1 files (n=40) were used. The number of rotations to failure was analyzed by two-way ANOVA and independent sample t-test. F...

متن کامل

cyclic fatigue resistance and fractographic analysis of race and protaper rotary niti instruments

introduction: this study investigated the fatigue and fracture modes of race and protaper rotary instruments. materials & methods: fatigue resistance was evaluated by rotating the files 30 ° or 60 ° and with 2 or 5mm radius of curvature. race taper 06 size 25 and protaper f1 files (n=40) were used. the number of rotations to failure was analyzed by two-way anova and independent sample     t-tes...

متن کامل

Influence of a glide path on the dentinal crack formation of ProTaper Next system.

OBJECTIVES The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. MATERIALS AND METHODS Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teet...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 4

صفحات  152- 158

تاریخ انتشار 2017-09-29

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023