Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm

نویسندگان

  • Sajjad Dadfar Ministry of Energy, IRAN Power Generation Transmission and Distribution Management Company (TAVANIR) Tehran, Iran
چکیده مقاله:

Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does the using of fault current limiter reduce the pressure on network equipment, but also it can provide a connection to improve the function of the system. There are different types of superconducting fault current limiter, which are made of various superconducting materials and with different designs. Superconducting fault current limiter can be categorized as resistive, inductive and bridge. In this research, the effect of superconducting fault current limiter factors investigated on transient recovery voltage, voltage drop and transient behavior of wind turbine systems based on fixed speed wind turbines, in order to study the behavior of all three types of superconducting fault current limiter that was installed in distributed generation systems. The simulation results show that the transient recovery voltage, the voltage drop and the transient behavior of fixed speed wind turbines have been improved using superconducting fault current limiter

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

Series Resonance Based Fault Current Limiter with Controlling The Point of Common Coupling Voltage

This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...

متن کامل

the impact of superconducting fault current limiter locations on voltage sag in power distribution system

in this paper, the impacts of installing superconducting fault current limiter (sfcl)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (dg). among various sfcls, the hybrid type with a superconducting element in parallel with a current limiting reactor (clr) is selected. this is more effective than resisto...

متن کامل

Transient stability enhancement of DFIG based 10 MW wind farm by using of new inductive bridge type fault current limiter

Due to numerous advantages of the doubly-fed induction generator (DFIG), the application of DFIG based wind generator (WG) is increasing very rapidly. However, the transient stability is one of the major concerns of the DFIG based wind generator. Therefore to accomplish this goal, in this paper, an existing non-linear controller based new inductive bridge type fault current limiter (NC-NIBFCL) ...

متن کامل

Inter- Line Dynamic Voltage Restore and Fault Current Limiter (IDVR-FCL)

This paper proposes a novel combined device for fault current limiting and dynamic voltage restoring. It consists of a diode bridge superconducting fault current limiter and a dynamic voltage restorer, which both connected together via a common dc link. Interline FCL-DVR system is interlined between two different feeders that connected to a point of common coupling (PCC) in distribution network...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 07  شماره 01

صفحات  22- 28

تاریخ انتشار 2018-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023