Investigation of STATCOM effects on synchronous generator impedance based LOF relay with considering a realistic model for the excitation system of the generator

نویسندگان

چکیده مقاله:

This paper studies the effects of static synchronous compensator (STATCOM) on synchronous generator conventional loss of field (LOF) protection. To accomplish a comprehensive study, a typical and realistic excitation system is considered for the generator by using the phase-domain generator model available in the real-time-digital-simulator. Using such a system, LOF phenomenon is realistically studied in accordance with IEEE Standard C37. 102-2016, and the generator dynamics along with the LOF relay performance are investigated through different types of complete and partial LOF failures. It is shown that STATCOM presence can cause two major impacts on the LOF protection; i) It imposes an additional time delay on the relay performance to detect the LOF failures, while the amount of such a time delay is dependent on the generator initial loading and the type of LOF failure, and ii) It might lead the generator to reach a new stable operating point (NSOP) during change-over from AVR to MVR mode. Both impacts and the related consequences are discussed in the paper and some solutions are suggested to deal with the probable negative aspects. The solutions comprises 1) employing an overloading relay to avoid thermal impacts on the stator windings and 2) employing an alarming scheme to avoid the undesirable effects, that the generator may experience during prolonged under-excitation operation in the probable NSOPs.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM

This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach

abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...

15 صفحه اول

The Influence of Impedance Values and Excitation System Tuning on Synchronous Generator Stability in Distribution Grids

Synchronous machines installed in recently developed small-scale hydro power plants in Norway have relatively high values of the synchronous reactances, as well as the sub-transient and transient reactances. Typical synchronous reactance is 2 – 2.5 pu, but values up to 3.1 pu are experienced, which is 3 times the typical values for larger low-speed synchronous generators (with salient poles). H...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 1

صفحات  59- 70

تاریخ انتشار 2020-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023