Investigation the potential of Boron neutron capture therapy (BNCT) to treat the lung cancer

نویسندگان

  • Amir Danyaei Assistant Professor, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Farnaz Rahimli MSc Student, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Hojattolah Shabazian Associate Professor, Department of Clinical Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Mansour Zabihzadeh Associate Professor, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Associate Professor, Department of Clinical Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Mohammad Ali Behrooz Professor, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
چکیده مقاله:

Introduction: Boron neutron capture therapy (BNCT) is recommended to treat the glioblastoma tumor. It is well known that neuron beams are more effective treatment than photon beams to treat hypoxia tumors due to interaction of neutron with nucleus and production of heavy particles such as 7Li and alpha particle. In this study to evaluate the suitability of BNCT for treating of lung cancer, the dose distributions of neutron beam were calculated in lung tumor volume and in peripheral organs at risk (OARs). Materials and Methods: Dose distribution in Boron neutron capture therapy to treat lung cancer was calculated by MCNPX (2.6.0) code. A 3×3×3 cm3 tumor was located in left lung of ORNL phantom and was irradiated with a rectangular field of neutron positioned at surface source distance (SSD) of 10 cm. recommended spectrum of MIT (Massachusetts Institute of Technology) was used. Tumor was loaded with different concentrations of Boron 0, 10, 30 and 60 ppm. Dose delivered to OARs such as heart, spinal cord, right lung … were calculated. Results: The results show that neutron flux significantly decreased followed to penetrate in lung tissue. Neutron flux decreased in all energy bins of irradiated MIT spectrum; maximum fall- off occurred in the range of epithermal energy. Dose distribution was not depended to SSD. The absorbed dose in tumor was 2.16×10-14, 2.6×10-14, 3.44×10-14 and 4.72×10-14 Gy(per one irradiated neutron from source) for boron concentration of 0, 10, 30 and 60 ppm, respectively. From the OARs, the heart tissue absorbed the maximum dose of 1.66×10-15 Gy (per one irradiated neutron from source). Conclusion: Our simulated model was successful to calculated organ doses in BNCT. As the boron concentration in lung tumor increases, absorbed dose increased while dose uniformity trended downward. Our results show that the MIT neutron source is suitable to treat deep lung tumors while OVRs’ dose maintains within the threshold dose.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

شبیه سازی چشمه 7li(p,n)7be جهت استفاده در bnct (boron neutron capture therapy)

با توجه به اینکه امروزه بیماران بسیاری در سراسر جهان از سرطان رنج میبرند،دانشمندان در تلاشند روشهای درمانی جدیدتر و بهتری را کشف کنند .یکی از این روشها "درمان بوسیله گیراندازی نوترون توسط بور (bnct)" نام دارد که میتواند یکی از بهترین روشهای مفید و موثر و جایگزین در درمان سرطانهایی از نوع glioblastoma و melanoma نسبت به روشهای متداولی چون شیمی درمانی یا رادیوتراپی باشد.در این روش هدف انجام واکنش...

an investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

background: the aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or pmma), a150 plastic and te- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. materials and methods: thermal neutron fluence, photon dose and epithermal neut...

متن کامل

Impacts of multiple-field irradiation and boron concentration on the treatment of boron neutron capture therapy for non-small cell lung cancer

Background: Boron neutron capture therapy (BNCT) is a radiotherapy that combines biological targeting and high linear energy transfer. A potential therapeutic approach for non-small cell lung cancer (NSCLC) is considered. However, dose in lung tumor is not homogeneous, and it will reduce the effect of BNCT treatment. In order to improve the dose distribution of BNCT, the multi-field irradiation...

متن کامل

Boron Neutron Capture Therapy (BNCT) - Low-Energy Neutron Spectrometer for Neutron Field Characterization -∗)

Boron Neutron Capture Therapy (BNCT) is known to be a promising and new cancer therapy which can kill tumor cells suppressing damage to normal tissues. Recently, accelerator based neutron sources (ABNS) for BNCT are under development especially in Japan. For characterization of the neutron field, we carried out the series study concerning thermal/epi-thermal neutron spectrometry especially for ...

متن کامل

Boron Neutron Capture Therapy

A project aimed at the development of an accelerator facility devoted to Boron Neutron Capture Therapy (BNCT) is ongoing at the National Atomic Energy Commission of Argentina [1]. In a first stage of development, the accelerator will be capable of delivering proton or deuteron beams of 30 mA at about 1.4 MeV which is suitable for neutron production through the 9Be(d,n) reaction. In this context...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  79- 79

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.