Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

نویسندگان

  • Hassan Zarghani Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, Iran
چکیده مقاله:

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments in Sabzevar County, Iran. The entrance skin dose (ESD) distributions were determined by use of thermoluminescence dosimeter (TLD) chips for 10 standard projections (i.e., anterioposterior [AP] abdomen, AP and posteroanterior [PA] chest, AP and lateral [LAT] lumbar spine, AP pelvis, cervical AP, cervical LAT, as well as AP and LAT skull). The third quartiles of the measured ESDs were compared with the previously published data. Results: In the present study, the third quartile of the measured ESDs for the patients undergoing specific examination were selected as LDRLs. The calculated LDRLs for the chest PA, chest AP, lumbar spine PA, lumbar spine LAT, pelvis AP, abdomen AP, cervical AP, cervical LAT, skull PA, and skull LAT were 0.54, 0.64, 1.99, 3.83, 1.47, 2.15, 0.54, 0.78, 1.22, and 1.01 mGy, respectively. Conclusion: Our results were compared with the DRLs reported in Iran, UK, and Japan as well as those reported by the National Radiological Protection Board (NPRB) for the UK. The ESDs obtained in this study for the chest PA, cervical AP, cervical LAT, AP and LAT skull, abdomen AP, pelvis AP, lumbar PA, and lumbar LAT examinations did not exceed the DRL values reported by NPRB. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

local diagnostic reference levels for common pediatric x-ray examinations in khorasan razavi province, iran

introduction given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. diagnostic reference level (drl) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Excess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County

Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...

متن کامل

Diagnostic reference levels for X-ray examinations in Slovenia

Background. Medical applications of ionizing radiation are by far the largest man-made source of radiation exposure for the population in most developed countries. A good practice in diagnostic radiology should produce an image containing all necessary information needed for accurate diagnosis and should result in the minimum dose to the patient. After introduction of diagnostic reference level...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 1

صفحات  62- 65

تاریخ انتشار 2018-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023