Methylene Blue Based Device for Pathogen Reduction in Human Plasma

نویسندگان

  • A Elikaei
  • A Asadollahi
  • H Latifi
  • H Mirshafiee
  • H Nikbakht
  • S M Hosseini
  • Z Sharifi
چکیده مقاله:

Abstract Background Despite improvement in safety of plasma transfusion some virus transmission still remains a problem. So as World Health Organization (WHO) recommends, many countries developed Pathogen Reduction Technologies (PRT) to inactivate pathogens, in plasma components. The Methylene Blue (MB) based methods is one of the most universal one. The purpose of this research was, produce a device that can inactivate viruses in MB environment. Materials and Methods In this interventional study, each Plasma Sample was illuminated by 70Pieces (PCs) of 1 w red Light Emitting Diodes (LEDs) from one side. These LEDs emit light at central wavelength of 627 nm with 20 nm Full Width at Half Maximum (FWHM). Two model viruses Herpes Simplex Virus (HSV) and Vesicular Stomatitis Virus (VSV) were used and Tissue Culture 50% Infection Dose (TCID50) was used to calculate virus Log reduction. Two concentration of MB and 5 different illumination times were used. Results In 10 µm concentration of MB, HSV had 6.00±0.2 maximum log reduction that obtain after 60 minutes illumination and VSV had 5.50±0.3 maximum log reduction after 75 minutes illumination. In 1 µM concentration of MB, HSV had 5.20±0.3 maximum log reduction that obtain after 60 minutes illumination and VSV had 4.90±0.2 maximum log reduction after 75 minutes illumination. Conclusion Results of virus inactivation in this method were similar to other methods (P-value0.05 in comparison with Theraflex), and it showed this device could inactivate viruses according to WHO recommendation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

inactivation of model viruses suspended in fresh frozen plasma using novel methylene blue based device.

background and objective: there is a concern on safety of human fresh frozen plasma (ffp) as it is a source of some medicinal products. the possibility of transmission of blood-borne are reported often due to emerging viruses. there are some pathogen reduction technologies (prt) to inactivate viruses. methylene blue (mb) based method is one of them. the aim of this study was to examine new desi...

متن کامل

Inactivation of model viruses suspended in fresh frozen plasma using novel methylene blue based device

BACKGROUND AND OBJECTIVE There is a concern on safety of human Fresh Frozen Plasma (FFP) as it is a source of some medicinal products. The possibility of transmission of blood-borne are reported often due to emerging viruses. There are some Pathogen Reduction Technologies (PRT) to inactivate viruses. Methylene Blue (MB) based method is one of them. The aim of this study was to examine new desig...

متن کامل

Reduction and uptake of methylene blue by human erythrocytes.

A thiazine dye reductase has been described in endothelial cells that reduces methylene blue (MB), allowing its uptake into cells. Because a different mechanism of MB uptake in human erythrocytes has been proposed, we measured MB uptake and reduction in this cell type. Oxidized MB (MB(+)) stimulated reduction of extracellular ferricyanide in a time- and concentration-dependent manner, reflectin...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 3

صفحات  97- 102

تاریخ انتشار 2013-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023