MRS Shimming: An Important Point Which Should not be Ignored

نویسندگان

  • B Zeinali-Rafsanjani
  • L Mina
  • M A Mosleh-Shirazi
  • M Saeedi-Moghadam
  • R Faghihi
  • R Jalli
چکیده مقاله:

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a process known as shimming. This study is intended to recall the importance of shimming and also the significant role of quality control (QC) in achieving an accurate quantification.Material and Method: An acrylic cylindrical quality control phantom was designed as an analog of brain MRS test phantoms in order to control the accuracy of the obtained signal of a 1.5 T Siemens MRI system which belonged to one of Shiraz hospitals. The signal of NAA, Cho, Cr, the combination of these metabolites and also the distilled water, which was used in this study, was evaluated using separate phantoms. A QC test was performed using Siemens QC phantom and a standard test phantom.Results: The spectrum of our home- made phantom had a significant difference with the expected spectrum. The results of checking the spectrum of metabolites separately also confirmed that there was a systemic problem that affects all the signals originated from all metabolites and even the pure distilled water. The MRS system could not pass QC tests, and peak broadening was common in all spectra. The complex spectrum of standard test phantom was not produced successfully by the MRS system.Discussion: By a simple check of the water peak characteristics, lots of information can be obtained, one of which is the status of shimming that has a considerable effect on the accuracy of the spectrum. Thus, performing an automatic or manual shimming is not a criterion of the spectrum accuracy, and performing a periodic quality control using a test phantom by a specialist  is necessary.Conclusion: Briefly, the quality control of MRS and all the other clinical device must be taken seriously. Sometimes QC can be the boundary of a right or a wrong decision for the patient.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Pancreatitis – A Disease That Should Not Be Ignored!

Last week I reviewed a relatively unknown household threat to dogs and cats – bread dough intoxication. More commonly around the holidays emergency rooms see a spike in a specific type of illness in our furry companions – acute pancreatitis. This illness can manifest at any time of year, but incidence around the major winter holidays in the United States is so high that many refer to the days a...

متن کامل

Why non-determinism in middleware should not be ignored

Unfortunately, in the practical world of IT, the theoretical solution does not apply. Indeed the cost of resolving the difficulties raised by non-determinism rapidly become prohibitive as the number of ‘components’ which need to work together rises. This is particularly applicable to distributed systems connected by middleware, with major implications for project management, application maintai...

متن کامل

Takayasu Arteritis: Criteria for Surgical Intervention Should Not Be Ignored

Takayasu aortoarteritis is a rare, chronic granulomatous panarteritis with significant morbidity amongst young patients. Current challenges include a lack of awareness about the condition, delays in diagnosis due to its varied presentation, and suboptimal methods for assessing disease activity. The development of noninvasive imaging including magnetic resonance angiography and positron emission...

متن کامل

Shimming and MRS

Adjustment of the static magnetic field homogeneity, commonly known as the B0 shimming or simply shimming, is essential for magnetic resonance spectroscopy because it determines the spectral resolution which is critical for reliable metabolite quantification. Inhomogeneities in the B0 field, resulting primarily from susceptibility differences between air and tissue, are scaled with the B0 field...

متن کامل

I-14: Assisted Reproduction and Religion What Consideration Should Be and Should Not Be Relevant,

Several important issues are pertinent to an ethical discussion of the new technology today grouped under the name Assisted Reproduction Technology (ART). This is a moral imperative because each of us must decide what is to be considered ethically acceptable in assisted reproduction. Reflecting on the ethical dimension of ‘creating’ a new human life can play a major role in ensuring that in eac...

متن کامل

Different Stroke Scales; Which Scale or Scales Should Be Use?

Background: There has been considerable development in the clinometric of stroke. But, researcher is concerned that some scales are too generic, inherently and the insight may not be provided. The current study was conducted to determine which scale or scales should be used in stroke survivors. Methods: We selected 67 studies which published between January 2010 and December 2018 from Up to d...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 3

صفحات  -

تاریخ انتشار 2018-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023