چکیده مقاله:

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy function which leads to unsatisfactory results.Objective: We propose in this paper a new approach for the generation of a pseudo-CT image from an MR image.Materials and Methods: This approach is based on a dense stereo matching concept, for that, we encode each pixel according to a shape related coordinates method, and we apply a local texture descriptor to put into correspondence pixels between MRI patient and MRI atlas images. The proposed approach was tested on a real MRI data, and in order to show the effectiveness of the proposed local descriptor, it has been compared to three other local descriptors: SIFT, SURF and DAISY. Also it was compared to registration method.Results: The calculation of structural similarity (SSIM) index and DICE coefficients, between the pseudo-CT image and the corresponding real CT image show that the proposed stereo matching approach outperforms a registration one.Conclusion: The use of dense matching with atlas promises good results in the creation of pseudo-CT. The proposed approach can be recommended as an alternative to registration techniques.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

new pseudo-ct generation approach from magnetic resonance imaging using a local texture descriptor

background: one of the challenges of pet/mri combined systems is to derive an attenuation map to correct the pet image. for that, the pseudo-ct image could be used to correct the attenuation. until now, most existing scientific researches construct this pseudo-ct image using the registration techniques. however, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Magnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach

Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

Texture analysis methodologies for magnetic resonance imaging

Methods for the analysis of digital-image texture are reviewed. The functions of MaZda, a computer program for quantitative texture analysis developed within the framework of the European COST (Cooperation in the Field of Scientific and Technical Research) B11 program, are introduced. Examples of texture analysis in magnetic resonance images are discussed.

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 1

صفحات  -

تاریخ انتشار 2018-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023