Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

نویسندگان

  • Mahbod Esfahani M.Sc.in Medical Physics, Radiotherapy Dept., Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
  • Mahmoud Allahverdi Associate Professor, Medical Physics Dept., Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Mehdi Aghili Assistant Professor, Radiotherapy Dept., Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
  • Somayeh Nourollahi M.Sc.in Medical Physics, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Vahid Changizi Assistant Professor, Radiology Technology Dept., Faculty of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and tangential fields, utilizing Gafchromic EBT film for dosimetry. Material and Methods: In this study, a slab phantom was designed with lung- and heart-equivalent inhomogetenities. Our measurements were carried out using Gafchromic EBT film. Irradiations were performed using the 6 MV photon beam of a Varian 2100 Clinac linear accelerator. Three-dimensional treatment planning and dose calculations were carried out using the RT Dose Plan software. The conventional method with source-to-skin distance match and a 3D method with source-to-axis distance match under different combinations of parameters such as gantry, collimator and couch rotations as well as asymmetric fields were utilized. Results: The results demonstrated differences between the 3D and conventional techniques. The best results in the match region were observed using the 3D method with asymmetric technique (maximum area of overlap = 0.43 cm2, depth of overlap = 3.55 cm, and average width of overlap = 0.75 cm). Discussion and Conclusion: This study shows that the EBT film is a suitable tool for two-dimensional distribution dosimetry and relative dose measurements. The study shows difficulties in achieving a homogenous dose distribution in the match region of supraclavicular and tangential fields and also demonstrates the effects of setup parameters on matching of treatment fields.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

optimization of 3d planning dosimetry in a breast phantom for the match region of supraclavicular and tangential fields

introduction: the complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (ptv) result in perturbations in dose distribution. this problem can result in overdosage or underdosage in the match region of the three treatment fields. the purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

Optimization of three dimensional planning dosimetric in breast phantom for match region of supraclavicular and tangential fields.

AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatom...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region

چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...

15 صفحه اول

Comparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 3

صفحات  73- 81

تاریخ انتشار 2011-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023